Detailed Information

Cited 4 time in webofscience Cited 5 time in scopus
Metadata Downloads

Comparison of submillisievert CT with standard-dose CT for urolithiasis

Authors
Shim, Young SupPark, So HyunChoi, Seung JoonAhn, Su JoaPak, Seong YongJung, HanPark, Seong Ho
Issue Date
Aug-2020
Publisher
SAGE PUBLICATIONS LTD
Keywords
Urolithiasis; computed tomography; X-ray; radiation dose reduction; model-based iterative reconstruction; iterative reconstruction technique
Citation
ACTA RADIOLOGICA, v.61, no.8, pp.1105 - 1115
Journal Title
ACTA RADIOLOGICA
Volume
61
Number
8
Start Page
1105
End Page
1115
URI
https://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/17847
DOI
10.1177/0284185119890088
ISSN
0284-1851
Abstract
Background Patients with renal stones receive multiple computed tomography (CT) examinations. We investigated whether submillisievert (sub-mSv) CT for stone detection could reduce radiation dose at exposure levels comparable to kidney, ureter, and bladder (KUB) radiography. Purpose To evaluate the radiation dose exposure, diagnostic performance, and image quality of sub-mSv non-contrast CT using advanced modelled iterative reconstruction algorithm with spectral filtration for the detection of urolithiasis. Material and Methods A total of 145 consecutive patients underwent non-contrast CT using a third-generation dual-source scanner to obtain two datasets, i.e. 16.7% (sub-mSv CT, tube detector A) and 100% (standard-dose CT, combination of tube detector A and B) tube loads with spectral filtration. The performance of sub-mSv CT for the detection of stones was analyzed by two readers and compared with that of standard-dose CT. Image quality was measured subjectively and objectively. Results In total, 171 stones were detected in 79 patients. The mean effective radiation doses of sub-mSv CT was 0.3 mSv. The sensitivity and specificity values for diagnosis of stones measuring >= 3 mm was 95.1% and 100% for sub-mSv CT. The sensitivity and specificity for all stone detection was 74.9% and 97.8%, respectivey, for sub-mSv CT. The image quality was lower for sub-mSv CT than for standard-dose CT (P < 0.01). Conclusion Sub-mSv CT can be achieved with radiation doses close to KUB radiography. Sub-mSv CT with spectral filtration can be used to detect stones measuring >= 3 mm and be used as a follow-up imaging modality as an alternative to KUB radiography.
Files in This Item
There are no files associated with this item.
Appears in
Collections
의과대학 > 의학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Jung, Han photo

Jung, Han
College of Medicine (Department of Medicine)
Read more

Altmetrics

Total Views & Downloads

BROWSE