Detailed Information

Cited 6 time in webofscience Cited 10 time in scopus
Metadata Downloads

Multi-atlas cardiac PET segmentation

Authors
Kim, Sally Ji WhoSeo, SeonghoKim, Hyeon SikKim, Dong-YeonKang, Keon WookMin, Jung-JoonLee, Jae Sung
Issue Date
Feb-2019
Publisher
ELSEVIER SCI LTD
Keywords
Segmentation; Myocardial PET; Atlas; Quantification
Citation
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, v.58, pp.32 - 39
Journal Title
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS
Volume
58
Start Page
32
End Page
39
URI
https://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/1925
DOI
10.1016/j.ejmp.2019.01.003
ISSN
1120-1797
Abstract
Purpose: We propose a multi-atlas based segmentation method for cardiac PET and SPECT images to deal with the high variability of tracer uptake characteristics in myocardium. In addition, we verify its performance by comparing it to the manual segmentation and single-atlas based approach, using dynamic myocardial PET. Methods: Twelve left coronary artery ligated SD rats underwent ([F-18]fluoropentyl) triphenylphosphonium salt PET/CT scans. Atlas-based segmentation is based on the spatial normalized template with pre-defined region-of-interest (ROI) for each anatomical or functional structure. To generate multiple left ventricular (LV) atlases, each LV image was segmented manually and divided into angular segments. The segmentation methods performances were compared in regional count information using leave-one-out cross-validation. Additionally, the polar-maps of kinetic parameters were estimated. Results: In all images, the highest r(2) template yielded the lowest root-mean-square error (RMSE) between the source image and the best-matching templates ranged between 0.91-0.97 and 0.06-0.11, respectively. The single-atlas and multi-atlas based ROIs yielded remarkably different perfusion distributions: only the multi-atlas based segmentation showed equivalent high correlation results (r(2) = 0.92) with the manual segmentation compared with the single-atlas based (r(2) = 0.88). The high perfusion value underestimation was remarkable in single-atlas based segmentation. Conclusions: The main advantage of the proposed multi-atlas based cardiac segmentation method is that it does not require any prior information on the tracer distribution to be incorporated into the image segmentation algorithms. Therefore, the same procedure suggested here is applicable to any other cardiac PET or SPECT imaging agents without modification.
Files in This Item
There are no files associated with this item.
Appears in
Collections
ETC > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE