프랑스 다중이용시설의 피난 및 마감재료 기준에 관한 연구A Study on the Evacuation and Interior Finish Standards of the Multi-use Facilities in France

Other Titles
A Study on the Evacuation and Interior Finish Standards of the Multi-use Facilities in France
Authors
김령우김용성
Issue Date
2019
Publisher
한국실내디자인학회
Keywords
Life safety codes; means of egress; occupant load; traffic units; the interior finish standards; the standards of facilities; 피난안전법; 피난방법; 수용인원; 통행단위 기준; 마감재 기준; 설비기준
Citation
한국실내디자인학회 논문집, v.28, no.6, pp.196 - 207
Journal Title
한국실내디자인학회 논문집
Volume
28
Number
6
Start Page
196
End Page
207
URI
https://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/19272
ISSN
1229-7992
Abstract
The laws and regulations on building and interior architecture should successfully provide the means of egress, in particular, to enable people to quickly evacuate in the fire and crisis situations, along with the standards of facilities and interior finishing materials in building that respond most immediately in case of fire. This study researched, through literature and information, the traffic units, which are the regulations related to evacuation, and the installation of entrance and stairs in the interior architecture of the multi-use facilities in France. In addition, the standards of fire extinguishing system such as fire alarm facility and smoke detector installation were considered according to the classification of finishing materials in architecture and the changed conditions and risk of finishing materials in case of fire. Accordingly, the classification and regulations of multi-use facilities were studied based on the facility use and occupant load in architecture. Therefore, the regulations of France are divided the strict facility regulations of the elderly, disabled, and children’s facilities and the finishing materials of interior architecture in multi-use facilities into six stages of material ranges based on and combustibility and flammability. In the case of general housing, smoke detectors are required to be installed, and the installation standards of smoke detectors have been operated as being defined by multi-use facility. Therefore, in this study, the regulations and design plans to be considered in the fire and emergency evacuation situation were studied, focusing on the provisions related to evacuation influencing the design stage of architects in the means of egress of the multi-use facilities in France.
Files in This Item
There are no files associated with this item.
Appears in
Collections
공과대학 > 건축학부 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Yong Sung photo

Kim, Yong Sung
Engineering (Division of Architecture & Architectural Engineering)
Read more

Altmetrics

Total Views & Downloads

BROWSE