Posterior Correction of Adolescent Idiopathic Scoliosis with High-Density Pedicle Screw-Only Constructs: 5 Years of Follow-UpPosterior Correction of Adolescent Idiopathic Scoliosis with High-Density Pedicle Screw-Only Constructs: 5 Years of Follow-Up
- Other Titles
- Posterior Correction of Adolescent Idiopathic Scoliosis with High-Density Pedicle Screw-Only Constructs: 5 Years of Follow-Up
- Authors
- 백종민; 황창주; 조재환; 윤소정; 이동호; 이춘성
- Issue Date
- Apr-2020
- Publisher
- 연세대학교의과대학
- Keywords
- Adolescent idiopathic scoliosis; pedicle screw; high-density; posterior-only surgery
- Citation
- Yonsei Medical Journal, v.61, no.4, pp.323 - 330
- Journal Title
- Yonsei Medical Journal
- Volume
- 61
- Number
- 4
- Start Page
- 323
- End Page
- 330
- URI
- https://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/26301
- DOI
- 10.3349/ymj.2020.61.4.323
- ISSN
- 0513-5796
- Abstract
- Purpose: This study aimed to analyze radiological outcomes in patients with adolescent idiopathic scoliosis (AIS) who underwent posterior correction with high-density pedicle screw-only constructs. We hypothesized that high-density pedicle screw-only constructs in AIS would provide a high correction rate and would facilitate the maintenance of the correction or obviate the loss thereof.
Materials and Methods: We retrospectively analyzed radiological outcomes over a minimum follow-up period of 5 years in patients with AIS who underwent posterior correction with high-density pedicle screw-only constructs. A total of 124 consecutive patients were included. Demographic data, including age, sex, operated fusion level, numbers of screw, Lenke curve type, Risser stage, and follow-up period were retrospectively collected from electronic medical records and radiological measurements including serial follow-up.
Results: The average number of pedicle screws was 1.96/vertebra. The average curve correction was 48.3% for the proximal thoracic (PT) curve, 83.1% for the main thoracic (MT) curve, and 80.2% for the thoracolumbar/lumbar (TL/L) curve at final followup. Use of high-density pedicle screw-only constructs helped achieve excellent correction rates, with no significant loss of correction at final follow-up.
Conclusion: We obtained excellent correction rates of 48.3% for PT, 83.1% for MT, and 80.2% for TL/L curves using high-density pedicle screw-only constructs in AIS, with no significant loss of correction at final follow-up.