Detailed Information

Cited 4 time in webofscience Cited 4 time in scopus
Metadata Downloads

Feasibility of fast non-local means noise reduction algorithm in magnetic resonance imaging using 1.5 and 3.0 T with diffusion-weighted image technique

Authors
Choi, Won HoChoi, Hye RanSeo, EunsooHwang, JeewooOh, HeekyungKim, Myeong RaeHan, Su RinKim, Min SeokKang, Seong-HyeonLee, Youngjin
Issue Date
2019
Publisher
ELSEVIER GMBH
Keywords
Magnetic resonance image (MRI); Diffusion weighted image (DWI); B-value; Fast non-local means (FNLM) algorithm; Noise reduction; Quantitative evaluation of image quality
Citation
OPTIK, v.183, pp.241 - 246
Journal Title
OPTIK
Volume
183
Start Page
241
End Page
246
URI
https://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/2880
DOI
10.1016/j.ijleo.2019.02.036
ISSN
0030-4026
Abstract
Magnetic resonance imaging (MRI) has many advantages and has developed various pulse sequences. In particular, the diffusion weighted image (DWI) technique is widely used because it can acquire images quickly during examination of stroke, through a proper adjustment of the diffusion-weighted gradient b-value. However, a setting with inappropriate b-value causes loss of image signal that increases the influence of noise. Therefore, in this study, we quantitatively evaluated image quality after applying a variety of algorithms to the image acquired by changing the b-value and the main magnetic field in the MRI device. To acquire the image, the phantom was self-produced with an acrylic panel and chicken breast. Wiener filter, total variation (TV), and our proposed fast non-local means (FNLM) noise reduction algorithms were applied to the image. Consequently, the signal intensity at a 3.0 T magnetic field increased by a factor 4.8 compared to a 1.5 T magnetic field. Moreover, the signal-to-noise ratio and contrast-to-noise ratio were highest with the FNLM algorithm, and the values increased by factors of 9.5 and 9.9 with a 1.5 T magnetic field and by factors of 9.9 and 5.0 with a 3.0 T magnetic field compared to the noise image, respectively. The result of time resolution, the Wiener filter appeared the finest value, but had no significant difference compared to FNLM algorithm. In conclusion, our results confirmed that the proposed FNLM noise reduction algorithm can acquire both improved image quality and high processing time in MRI imaging with the DWI technique.
Files in This Item
There are no files associated with this item.
Appears in
Collections
보건과학대학 > 방사선학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Youngjin photo

Lee, Youngjin
Health Science (Dept.of Radiology)
Read more

Altmetrics

Total Views & Downloads

BROWSE