Detailed Information

Cited 7 time in webofscience Cited 6 time in scopus
Metadata Downloads

Anatomic double-bundle medial patellofemoral ligament reconstruction with aperture fixation using an adjustable-length loop device: a 2-year follow-up study

Authors
Sim, Jae-AngLim, Jin-KyuLee, Byung Hoon
Issue Date
25-Sep-2018
Publisher
BMC
Keywords
Medial patellofemoral ligament; Patella; Recurrent patellar dislocation; Double bundle; Aperture fixation; Adjustable-length loop device
Citation
BMC MUSCULOSKELETAL DISORDERS, v.19
Journal Title
BMC MUSCULOSKELETAL DISORDERS
Volume
19
URI
https://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/3329
DOI
10.1186/s12891-018-2261-x
ISSN
1471-2474
Abstract
Background: To assess the clinical availability of an adjustable-length loop device for use in the double-bundle technique with aperture fixation at the patella and femur during anatomic double-bundle medial patellofemoral ligament reconstruction (DB-MPFLR) for recurrent patellar dislocation. Methods: We retrospectively investigated 11 patients (12 knees) with recurrent patellar dislocation who underwent anatomic DB-MPFLR with an ipsilateral semitendinosus tendon autograft. The graft was folded in half, and its central portion was hanged using the adjustable-length loop device. Both free ends of the graft were fixed at the proximal and distal ends of the medial edge of the patella by using suture anchors, and the hanged graft loop was pulled into the femoral tunnel while maintaining equal tension on both bundles. Manual traction of the suture loops was applied to fix the graft appropriately in full range of motion (ROM) of the knee joint under arthroscopic guidance. Clinical outcomes such as re-dislocation, ROM, clinical scores (Kujala score, Lysholm score, and visual analogue scale score for anterior knee pain), and complications were assessed preoperatively and at 2 years postoperatively. Radiographic parameters indicating patellar position, including congruence angle and lateral patellofemoral angle, were measured at 4 different angles of knee flexion (30 degrees, 45 degrees, 60 degrees, and 90 degrees). Results: At 4 different flexion angles of the knee joint, the preoperative congruence angle decreased significantly and the lateral patellofemoral angle increased significantly at the final follow-up (P < 0.001). Notably, the improvements in these angles were maintained with no significant differences at the 4 different flexion angles. None of the patients experienced subluxation or re-dislocation after surgery. The patellar instability symptoms improved, as confirmed on the basis of radiographic and other clinical outcomes. Conclusion: New DB technique with aperture fixation at the patella and femur by using an adjustable-length loop device offers high stability with full ROM of the knee joint, can be considered as a feasible procedure and technique for recurrent patellar dislocation.
Files in This Item
There are no files associated with this item.
Appears in
Collections
의과대학 > 의학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Sim, Jae Ang photo

Sim, Jae Ang
College of Medicine (Department of Medicine)
Read more

Altmetrics

Total Views & Downloads

BROWSE