Detailed Information

Cited 4 time in webofscience Cited 7 time in scopus
Metadata Downloads

Development and Validation of Segmentation Method for Lung Cancer Volumetry on Chest CT

Authors
Kim, Young JaeLee, Seung HyunLim, kun YoungKim, Kwang Gi
Issue Date
Aug-2018
Publisher
SPRINGER
Keywords
Lung cancer; Response evaluation criteria in solid tumors; Tumor volume; Computed tomography; Computer-assisted diagnosis
Citation
JOURNAL OF DIGITAL IMAGING, v.31, no.4, pp.505 - 512
Journal Title
JOURNAL OF DIGITAL IMAGING
Volume
31
Number
4
Start Page
505
End Page
512
URI
https://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/3514
DOI
10.1007/s10278-018-0051-5
ISSN
0897-1889
Abstract
The set of criteria called Response Evaluation Criteria In Solid Tumors (RECIST) is used to evaluate the remedial effects of lung cancer, whereby the size of a lesion can be measured in one dimension (diameter). Volumetric evaluation is desirable for estimating the size of a lesion accurately. but there are several constraints and limitations to calculating the volume in clinical trials. In this study, we developed a method to detect lesions automatically, with minimal intervention by the user, and calculate their volume. Our proposed method, called a spherical region-growing method (SPRG), uses segmentation that starts from a seed point set by the user. SPRG is a modification of an existing region-growing method that is based on a sphere instead of pixels. The SPRG method detects lesions while preventing leakage to neighboring tissues, because the sphere is grown. i.e., neighboring voxels are added, only when all the voxels meet the required conditions. In this study, two radiologists segmented lung tumors using a manual method and the proposed method, and the results of both methods were compared. The proposed method showed a high sensitivity of 81.68-84.81% and a high dice similarity coefficient (DSC) of 0.86-0.88 compared with the manual method. In addition, the SPRG intraclass correlation coefficient (ICC) was 0.998 (CI 0.997-0.999, p < 0.01), showing that the SPRG method is highly reliable. If our proposed method is used for segmentation and volumetric measurement of lesions, then objective and accurate results and shorter data analysis time are possible.
Files in This Item
There are no files associated with this item.
Appears in
Collections
보건과학대학 > 의용생체공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Young Jae photo

Kim, Young Jae
IT (의공학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE