Detailed Information

Cited 17 time in webofscience Cited 21 time in scopus
Metadata Downloads

Personalized Urination Activity Recognition Based on a Recurrent Neural Network Using Smart Band

Authors
Whangbo, Taeg-KeunEun, Sung-JongJung, Eun-YoungPark, Dong KyunKim, Su JinKim, Chang HeeChung, Kyung JinKim, Khae-Hawn
Issue Date
Jul-2018
Publisher
KOREAN CONTINENCE SOC
Keywords
Urination recognition; Urination time; Mobile voiding hart; Recurrent neural network; Smart band
Citation
INTERNATIONAL NEUROUROLOGY JOURNAL, v.22, pp.S91 - S100
Journal Title
INTERNATIONAL NEUROUROLOGY JOURNAL
Volume
22
Start Page
S91
End Page
S100
URI
https://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/3602
DOI
10.5213/inj.1836168.084
ISSN
2093-4777
Abstract
Purpose: Though it is very important obtaining exact data about patients' voiding patterns for managing voiding dysfunction, actual practice is very difficult and cumbersome. In this study, data about urination time and interval measured by smart band device on patients' wrist were collected and analyzed to resolve the clinical arguments about the efficacy of voiding diary. By developing a smart band based algorithm for recognition of complex and serial pattern of motion, this study aimed to explore the feasibility of measurement the urination time and intervals for voiding dysfunction management. Methods: We designed a device capable of recognizing urination time and intervals based on specific postures of the patient and consistent changes in posture. These motion data were obtained by a smart band worn on the wrist. An algorithm that recognizes the repetitive and common 3-step behavior for urination (forward movement, urination, backward movement) was devised based on the movement and tilt angle data collected from a 3-axis accelerometer. The sequence of body movements during voiding has consistent temporal characteristics, so we used a recurrent neural network and long short-term memory based framework to analyze the sequential data and to recognize urination time. Real-time data were acquired from the smart band, and for data corresponding to a certain duration, the value of the signals was calculated and then compared with the set analysis model to calculate the time of urination. A comparative study was conducted between real voiding and device-detected voiding to assess the performance of the proposed recognition technology. Results: The accuracy of the algorithm was calculated based on clinical guidelines established by urologists. The accuracy of this detecting device was high (up to 94.2%), proving the robustness of the proposed algorithm. Conclusions: This urination behavior recognition technology showed high accuracy and could be applied in clinical settings to characterize patients' voiding patterns. As wearable devices are developed and generalized, algorithms detecting consistent sequential body movement patterns reflecting specific physiologic behavior might be a new methodology for studying human physiologic behavior.
Files in This Item
There are no files associated with this item.
Appears in
Collections
의과대학 > 의학과 > 1. Journal Articles
IT융합대학 > 컴퓨터공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Chang Hee photo

Kim, Chang Hee
College of Medicine (Department of Medicine)
Read more

Altmetrics

Total Views & Downloads

BROWSE