Detailed Information

Cited 9 time in webofscience Cited 9 time in scopus
Metadata Downloads

Rim Plate Augmentation of the Posterolateral Bare Area of the Tibial Plateau Using a 3.5-mm Precontoured Locking Compression Plate: A Cadaveric Study

Authors
Kim, YoungwooYoon, Yong-CheolCho, Jae-WooCho, Won-TaeJeon, Neung-HanOh, Chang-WugOh, Jong-Keon
Issue Date
May-2018
Publisher
LIPPINCOTT WILLIAMS & WILKINS
Keywords
tibia plateau; posterolateral fragment; anterolateral approach; rim plating
Citation
JOURNAL OF ORTHOPAEDIC TRAUMA, v.32, no.5, pp.E157 - E160
Journal Title
JOURNAL OF ORTHOPAEDIC TRAUMA
Volume
32
Number
5
Start Page
E157
End Page
E160
URI
https://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/3831
DOI
10.1097/BOT.0000000000001129
ISSN
0890-5339
Abstract
Objective: To evaluate the effectiveness of an additional rim plate [3.5-mm precontoured locking compression plate (LCP)] for stabilizing the posterolateral fragment in lateral tibial plateau fractures. Methods: Standard lateral locking plates [either a proximal tibial plate (PTP) or a proximal tibial locking plate (PTLP)] were applied to 40 matched pair knees from 20 fresh-frozen cadavers followed by the application of a secondary rim plate [variable angle LCP (VALCP)] posterior laterally. Results: The mean ratio of supported articular surface in the PTP group was 0.692, whereas that in the PTLP group was 0.569. This difference was statistically significant (P < 0.001). Additional rim plating with a VALCP could only be performed for 27 of 40 knees; 8 of 20 knees in the PTP group and 5 of 20 knees in the PTLP group could not be fitted with a VALCP due to anatomic limitations. For the total standard plating group alone, the mean ratio of supported articular surface was 0.596, whereas the mean ratio of supported articular surface with additional rim plating was 0.798 (P < 0.001). In contrast, additional rim plating was possible for more knees that received a PTLP than a PTP. Ultimately, there was no significant difference in the ratio of supported articular surface after additional rim plating between the 2 different types of standard plates (P = 0.087). Conclusion: Our results identified a bare area in the posterolateral corner of the lateral plateau that was unsupported by rafting screws following conventional, 3.5-mm, precontoured LCP plating. Thus, additional rim plating may be useful for treating plateau fractures with a posterolateral fragment.
Files in This Item
There are no files associated with this item.
Appears in
Collections
의과대학 > 의학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Yoon, Yong Cheol photo

Yoon, Yong Cheol
College of Medicine (Department of Medicine)
Read more

Altmetrics

Total Views & Downloads

BROWSE