Detailed Information

Cited 19 time in webofscience Cited 18 time in scopus
Metadata Downloads

A comparison between McGrath MAC videolaryngoscopy and Macintosh laryngoscopy in children

Authors
Kim, J. E.Kwak, H. J.Jung, W. S.Chang, M. Y.Lee, S. Y.Kim, J. Y.
Issue Date
Mar-2018
Publisher
WILEY
Citation
ACTA ANAESTHESIOLOGICA SCANDINAVICA, v.62, no.3, pp.312 - 318
Journal Title
ACTA ANAESTHESIOLOGICA SCANDINAVICA
Volume
62
Number
3
Start Page
312
End Page
318
URI
https://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/3977
DOI
10.1111/aas.13043
ISSN
0001-5172
Abstract
BackgroundThis prospective, randomised, controlled study was performed to evaluate the usefulness of the McGrath VL compared with Macintosh laryngoscopy in children with expected normal airway during endotracheal intubation, by comparing the time to intubation and difficulty of intubation. MethodsEighty-four patients aged 1-10 years who underwent endotracheal intubation for elective surgery were randomly assigned to the McGrath group (n = 42) or the Macintosh group (n = 42). Anaesthesia was induced with 2.5-3.0 mg/kg of propofol and sevoflurane 5-8 vol%. Orotracheal intubation was performed 2 min after injection of rocuronium 0.6 mg/kg with McGrath VL or Macintosh laryngoscope; the primary outcome was the time to intubation. The Cormack and Lehane glottic grade, intubation difficulty score (IDS), and success rate on intubation were assessed. Haemodynamic changes were also recorded. ResultsAs the primary outcome, median time to intubation [interquartile range] did not differ between the McGrath group and the Macintosh group (25.0 [22.8-28.3] s vs. 26.0 [24.0-29.0] s, P = 0.301). The incidence of grade I glottic view was significantly higher in the McGrath group than in the Macintosh group (95% vs. 74%, P = 0.013). Median IDS was lower in the McGrath group than in the Macintosh group (0 [0-0] vs. 0 [0-1], P = 0.018). There were no significant differences in success rate on intubation or haemodynamics between the two groups. ConclusionsMcGrath VL provides better laryngeal views and lower IDS but similar intubation times and success rates compared with the Macintosh laryngoscope in children with normal airway.
Files in This Item
There are no files associated with this item.
Appears in
Collections
의과대학 > 의학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Jung, Wol Seon photo

Jung, Wol Seon
College of Medicine (Department of Medicine)
Read more

Altmetrics

Total Views & Downloads

BROWSE