Detailed Information

Cited 1 time in webofscience Cited 1 time in scopus
Metadata Downloads

Non-contrast-enhanced peripheral MR angiography using velocity-selective excitation

Authors
Kim, DongchanSeo, HyunseokCho, JaejinKwon, KinamHan, YejiPark, HyunWook
Issue Date
Feb-2018
Publisher
WILEY
Keywords
golden-angle radial sampling; non-contrast-enhanced peripheral MRA; velocity-selective excitation
Citation
MAGNETIC RESONANCE IN MEDICINE, v.79, no.2, pp.779 - 788
Journal Title
MAGNETIC RESONANCE IN MEDICINE
Volume
79
Number
2
Start Page
779
End Page
788
URI
https://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/4123
DOI
10.1002/mrm.26732
ISSN
0740-3194
Abstract
PurposeTo develop a new non-contrast-enhanced peripheral MR angiography that provides a high contrast angiogram without using electrocardiography triggering and saturation radiofrequency pulses. MethodsA velocity-selective excitation technique is used in conjunction with the golden-angle radial sampling scheme. The signal amplitude varies according to the velocity of the flow by the velocity-selective excitation technique. Because the arterial blood velocity varies depending on the cardiac phase, the acquired data can be classified into systolic and diastolic phase based on the signal amplitude of the artery. Two images are then reconstructed from the systolic and diastolic phase data, respectively, and an image reflecting the differences between the two images is obtained to eliminate background and vein signals. The performance of the proposed method was compared with the quiescent-interval single shot (QISS) in eight healthy subjects and an elderly subject. ResultsThe proposed method generated fewer residual venous and background signals than the QISS. Furthermore, the maximum intensity projection images, the relative contrast, and the apparent contrast-to-noise ratio results showed that the proposed method produced a better contrast than the QISS. ConclusionsThe proposed non-contrast-enhanced peripheral MR angiography technique can provide a high contrast angiogram without the use of electrocardiography triggering and saturation radiofrequency pulses. Magn Reson Med 79:779-788, 2018. (c) 2017 International Society for Magnetic Resonance in Medicine.
Files in This Item
There are no files associated with this item.
Appears in
Collections
보건과학대학 > 의용생체공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Han, Ye Ji photo

Han, Ye Ji
College of IT Convergence (의공학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE