Detailed Information

Cited 25 time in webofscience Cited 28 time in scopus
Metadata Downloads

Comparison of 3D magnetic resonance imaging and digital subtraction angiography for intracranial artery stenosis

Authors
Park, Ji EunJung, Seung ChaiLee, Sang HunJeon, Ji YoungLee, Ji YeKim, Ho SungChoi, Choong-GonKim, Sang JoonLee, Deok HeeKim, Seon-OkKwon, Sun U.Kang, Dong-WhaKim, Jong S.
Issue Date
Nov-2017
Publisher
SPRINGER
Keywords
Intracranial stenosis; Magnetic resonance imaging; Angiography; Diagnosis; Stenosis
Citation
EUROPEAN RADIOLOGY, v.27, no.11, pp.4737 - 4746
Journal Title
EUROPEAN RADIOLOGY
Volume
27
Number
11
Start Page
4737
End Page
4746
URI
https://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/5523
DOI
10.1007/s00330-017-4860-6
ISSN
0938-7994
Abstract
Objectives To compare three-dimensional high-resolution magnetic resonance imaging (3D HR-MRI) and digital subtraction angiography (DSA) for diagnosing and evaluating stenosis in the entire circle of Willis. Methods The study included 516 intracranial arteries from 43 patients with intracranial artery stenosis (ICAS) who underwent both 3D HR-MRI and DSA within 1 month. Two readers independently diagnosed atherosclerosis, dissection, moyamoya disease and vasculitis, rated their diagnostic confidence for each vessel and measured the luminal diameters. Reference standard was made from clinico-radiologic diagnosis. Diagnostic accuracy, diagnostic confidence, the degree of stenosis and luminal diameter were assessed and compared between both modalities. Results For atherosclerosis, 3D HR-MRI showed better diagnostic accuracy (P = .03-.003), sensitivity (P = .006-.01) and positive predictive value (P <= .001-.006) compared to DSA. Overall, the readers were more confident of their diagnosis of ICAS when using 3D HR-MRI (reader 1, P <= .001-.007; reader 2, P <= .001-.015). 3D HR-MRI showed similar degree of stenosis (P > .05) and higher luminal diameter (P < .05) compared to DSA. Conclusions 3D HR-MRI might be useful to evaluate atherosclerosis, with better diagnostic confidence and comparable stenosis measurement compared to DSA in the entire circle of Willis.
Files in This Item
There are no files associated with this item.
Appears in
Collections
의과대학 > 의학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Jeon, Ji young photo

Jeon, Ji young
College of Medicine (Department of Medicine)
Read more

Altmetrics

Total Views & Downloads

BROWSE