Label-Free Optical Biochemical Sensors via Liquid-Cladding-Induced Modulation of Waveguide Modes

Authors
Nhu Hoa Thi TranKim, JisooThang Bach PhanKhym, SungwonJu, Heongkyu
Issue Date
20-Sep-2017
Publisher
AMER CHEMICAL SOC
Keywords
optical biochemical sensor; waveguide mode mismatch; label-free sensors; multimode optical fiber; refractometer; remote sensing
Citation
ACS APPLIED MATERIALS & INTERFACES, v.9, no.37, pp.31478 - 31487
Journal Title
ACS APPLIED MATERIALS & INTERFACES
Volume
9
Number
37
Start Page
31478
End Page
31487
URI
https://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/5699
DOI
10.1021/acsami.7b09252
ISSN
1944-8244
Abstract
We demonstrated modulation of the waveguide mode mismatch via liquid cladding of the controllable refractive index for label-free quantitative detection of concentration of chemical or biological substances. A multi mode optical fiber with its core exposed was used as the sensor head with the suitable chemical modification of its surface. Injected analyte liquid itself formed the liquid cladding for the waveguide. We found that modulation of the concentration of analyte injected enables a degree of the waveguide mode mismatch to be controlled, resulting in sensitive change in optical power transmission, which was utilized for its real-time quantitative assay. We applied the device to quantitating concentration of glycerol and bovine serum albumin (BSA) solutions. We obtained experimentally the limit of detection (LOD) of glycerol concentration, 0.001% (volume ratio), corresponding to the resolvable index resolution of similar to 1.02 x 10(-6) RIU (refractive index unit). The presented sensors also exhibited reasonably good reproducibility. In BSA detection, the sensor device response was sensitive to change in the refractive indices not only of liquid bulk but also of layers just above the sensing surface with higher sensitivity, providing the LOD experimentally as similar to 3.7 ng/mL (mass coverage of similar to 30 pg/mm(2)). A theoretical model was also presented to invoke both mode mismatch modulation and evanescent field absorption for understanding of the transmission change, offering a theoretical background for designing the sensor head structure for a given analyte. Interestingly, the device sensing length played little role in the important sensor characteristics such as sensitivity, unlike most of the waveguide-based sensors. This unraveled the possibility of realizing a highly simple structured label-free sensor for point-of-care testing in a real-time manner via an optical waveguide with liquid cladding. This required neither metal nor dielectric coating but still produced sensitivity comparable to those of other types of label-free sensors such as plasmonic fiber ones.
Files in This Item
There are no files associated with this item.
Appears in
Collections
바이오나노대학 > 나노물리학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Ju, Heong Kyu photo

Ju, Heong Kyu
BioNano Technology (Department of Physics)
Read more

Altmetrics

Total Views & Downloads

BROWSE