Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Facile and Precise Detection of Boric Acid via Coulometric Titration

Authors
Maeng, Ki RyongKim, Doo SooKim, Il TaeHur, Jae HyunKim, Ji HyeonBark, Chung WungPark, Sang Joon
Issue Date
Sep-2017
Publisher
AMER SCIENTIFIC PUBLISHERS
Keywords
Boric Acid; Coulombic Titration; Nuclear Reactor; Coolant; Real-Time
Citation
SCIENCE OF ADVANCED MATERIALS, v.9, no.9, pp.1546 - 1550
Journal Title
SCIENCE OF ADVANCED MATERIALS
Volume
9
Number
9
Start Page
1546
End Page
1550
URI
https://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/5799
DOI
10.1166/sam.2017.3168
ISSN
1947-2935
Abstract
In order to control the reactivity in a nuclear plant, boric acid is added to the reactor coolant in pressurized water reactors (PWRs); hence, the measurement of the boron concentration in the coolant is very important. In this work, a facile and precise coulometric titration technique was proposed by placing a silver anode and a graphite cathode in the same electrochemical cell, with the addition of NaBr as a scavenger for Ag+ ions. The concentration of boric acid was calculated from the number of electrons consumed in the electrochemical titration. It was found that the number of moles of electrons, and the boron concentration over a range of 5-50 ppm, conformed to a linear function with R-2 of 0.9960. This could be a potential method for the automation and remote control of the device responsible for measuring the boron concentration in the PWR coolant, without any loss of precision.
Files in This Item
There are no files associated with this item.
Appears in
Collections
IT융합대학 > 전기공학과 > 1. Journal Articles
공과대학 > 화공생명공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Il Tae photo

Kim, Il Tae
Engineering (화공생명배터리공학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE