Microfluidic neurotransmitters sensor in blood plasma with mediator-immobilized conducting polymer/N, S-doped porous carbon composite

Authors
Seo K.-D.Hossain M.M.Gurudatt N.G.Choi C.S.Shiddiky M.J.A.Park D.-S.Shim Y.-B.
Issue Date
Jun-2020
Publisher
Elsevier B.V.
Keywords
Alternating current induced separation; Electrochemical sensing; Evans blue; Microfluidic separation and sensing; Neurotransmitters; Screen printed device
Citation
Sensors and Actuators, B: Chemical, v.313
Journal Title
Sensors and Actuators, B: Chemical
Volume
313
URI
https://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/60206
DOI
10.1016/j.snb.2020.128017
ISSN
0925-4005
Abstract
A novel electrochemical microfluidic separation and sensing (EMSS) device was fabricated for monitoring neurotransmitters (NTs) in human blood plasma. Initially, the neurotransmitter separation was achieved with the AC field perturbation in a microfluidic channel followed by the successive detection using a sensor at the end of channel. The sensor performances using some of electron transfer mediators were demonstrated for sensing of seven NTs (5-hydroxytryptamine, dopamine, norepinephrine, epinephrine, 5-hydroxyindoleacetic acid, 5-hydroxytryptophan, and 3, 4-dihydroxy-L-phenylalanine). The sensor probe was fabricated by electropolymerization of 2, 2´:5´, 5″-terthiophene-3´-p-benzoic acid (TBA) with heteroatoms (N and S) doped porous carbon (HPC) to form a composite layer onto the screen printed carbon electrode, followed by covalent immobilization of a redox mediator. Among the tested mediators, Evans blue revealed the most superior performance. The parameters affecting the sensing performance were optimized, in terms of pH, temperature, fluid flow rate and AC parameters (i.e., frequency, amplitude, etc). The calibration plots for the seven NTs standard samples were found to be linear within the range of 0.05−130 nM with the detection limits between 0.034 (±0.005) and 0.044 (±0.004) nM. Finally, the reliability of the proposed device was assessed by detecting six NTs and two NTs derivatives in a human plasma sample. © 2020 Elsevier B.V.
Files in This Item
There are no files associated with this item.
Appears in
Collections
의과대학 > 의예과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Choi, Cheol Soo photo

Choi, Cheol Soo
College of Medicine (Premedical Course)
Read more

Altmetrics

Total Views & Downloads

BROWSE