Magnetic field sensitivity at 7-T using dual-helmholtz transmit-only coil and 12-channel receive-only bended coil

Authors
Kim, Kyoung-NamRyu, YeunchulSeo, Jeung-HoonKim, Young-Bo
Issue Date
Dec-2016
Publisher
WILEY-BLACKWELL
Keywords
MRI; dual-Helmholtz coil; birdcage coil; phased array coil; bended; magnetic flux
Citation
SCANNING, v.38, no.6, pp.515 - 524
Journal Title
SCANNING
Volume
38
Number
6
Start Page
515
End Page
524
URI
https://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/7633
DOI
10.1002/sca.21290
ISSN
0161-0457
Abstract
The purpose of this study was to combine a dual-Helmholtz (DH) transmit (Tx)-only coil and 12-channel receive (Rx)-only bended phased array (PA) coil to improve the magnetic flux (|B-1|) sensitivity in the superior-to-inferior (S-I) direction during human brain magnetic resonance imaging (MRI) at 7-T. The proposed coil combination was primarily implemented by electromagnetic (EM) simulation and compared with the 16-leg birdcage coil and 8-channel PA coil, which are generally used for the Tx- and Rx-only modes, respectively. The optimal coil combinations for the proposed structure were determined by |B-1| field calculations using the |B-T(+)| and |B-R(-)| fields, which are respectively the transmit and receive components of the |B-1| field. The coil performance was then evaluated by a bench test and 7-T MRI experiment. The results of the computational calculations indicated that the |B-T(+)| field of the DH coil was distributed similarly to that of the 16-leg birdcage coil despite the fewer conducting legs of the former. However, the 12-channel Rx-only bended PA coil had clearly higher |B-R(-)| profiles compared to the 8-channel PA coil. The results of the 7-T in vivo experiment showed that the proposed combination of the DH Tx-only coil and 12-channel Rx-only bended PA coil had better |B-1| field homogeneity in the sagittal slice as well as higher |B-1| field sensitivity during human brain MRI compared to an 8-channel Rx-only PA coil. SCANNING 38:515-524, (c) 2015 Wiley Periodicals, Inc.
Files in This Item
There are no files associated with this item.
Appears in
Collections
의과대학 > 의학과 > 1. Journal Articles
보건과학대학 > 방사선학과 > 1. Journal Articles
보건과학대학 > 의용생체공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Kyoung Nam photo

Kim, Kyoung Nam
College of IT Convergence (의공학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE