Clinical outcomes for endovascular repair of abdominal aortic aneurysm with the Seal stent graft

Authors
Kim, Jeong HoCho, Young KwonSeo, Tae-SeokSong, Myung GyuJeon, Yong SunHan, Young MinKang, Min HoLim, Hyoung Gun
Issue Date
Nov-2016
Publisher
MOSBY-ELSEVIER
Citation
JOURNAL OF VASCULAR SURGERY, v.64, no.5, pp.1270 - 1277
Journal Title
JOURNAL OF VASCULAR SURGERY
Volume
64
Number
5
Start Page
1270
End Page
1277
URI
https://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/7708
DOI
10.1016/j.jvs.2016.02.057
ISSN
0741-5214
Abstract
Objective: Since 2007, the availability of the Seal (S & G Biotech Inc, Seong-nam, Gyeonggi-do, Korea) stent graft for endovascular aneurysm repair (EVAR) has improved short-term outcomes in Korea. However, midterm outcome data are lacking. This retrospective study evaluated the midterm outcomes of 126 patients who underwent EVAR using the Seal stent graft between 2007 and 2010. Methods: Data regarding use of the Seal stent graft for EVAR were collected from 16 Korean centers, and were analyzed retrospectively using Kaplan-Meier and Cox univariate and multivariate analyses. Results: The mean patient age was 71 6 8 years (median, 70; range, 49-87 years). Patients who were treated using a bifurcated graft (113; 90%) were generally symptomatic (56; 44%, which included 13 ruptured abdominal aortic aneurysms [ 10%]) and male (105; 83%). The primary technical success rate was 99%. Four patients (3%) died within 30 days, 5 patients (4%) died after 30 days, and 12 patients (9%) were lost to follow-up. The survival rates were 97% 6 2% (1 month), 97% 6 2% (3 months), 96% 6 2% (6 months), 96% 6 2% (1 year), 94% 6 3% (3 years), and 81% 6 10% (5 years). During a mean follow-up of 55 6 22 months (median, 40; range, 0.03-91.2 months), 18 reinterventions were performed for 16 patients (13%). The freedom from reintervention rates were 96% 6 2% (1 month), 96% 6 2% (3 months), 94% 6 2% (6 months), 89% 6 3% (1 year), 84% 6 4% (3 years), and 57% 6 17% (5 years). The mean aneurysm diameter significantly decreased from 69.6 to 46.6 mm during the follow-up (P <.0001). A proximal neck of less than 15 mm, different simultaneous endoleaks, and insufficient bilateral coverage of the iliac aneurysm were associated with significantly higher rates of increased or unchanged aneurysm diameters (all P <.0001). Significantly higher rates of clinical failure were observed in patients who were less than 70 years old (P =.04), had a neck length of less than 15 mm (P =.02), and had a neck diameter of greater than 28 mm (P =.02). Conclusions: Most Seal stent grafts were implanted successfully (even in cases with a physical status of grade IV or higher or a ruptured abdominal aortic aneurysm), had an appropriate reintervention rate, and were stable during the midterm follow-up. However, there was a high rate of type I endoleak, which may be related to the early device model that we used. Therefore, long-term radiologic follow-up is recommended for the early detection of stent graft migration or endoleaks.
Files in This Item
There are no files associated with this item.
Appears in
Collections
의과대학 > 의학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Jeong Ho photo

Kim, Jeong Ho
College of Medicine (Department of Medicine)
Read more

Altmetrics

Total Views & Downloads

BROWSE