TRNSYS 건물 에너지 시뮬레이션 모델 캘리브레이션: GenOpt를 이용한 사례 연구A Model Calibration for Residential Building Energy Simulation : A Case Study with TRNSYS and Optimization Tool GenOpt

Other Titles
A Model Calibration for Residential Building Energy Simulation : A Case Study with TRNSYS and Optimization Tool GenOpt
Authors
임흥빈이경호공민석서동현
Issue Date
Aug-2019
Publisher
한국건축친환경설비학회
Keywords
Building energy simulation; Model calibration; Multi-zone calibration; TRNSYS simulation; GenOpt; 건물에너지 시뮬레이션; 모델 캘리브레이션; 다중 존 캘리브레이션; 트랜시스 시뮬레이션; 젠옵
Citation
한국건축친환경설비학회 논문집, v.13, no.4, pp.234 - 245
Journal Title
한국건축친환경설비학회 논문집
Volume
13
Number
4
Start Page
234
End Page
245
URI
https://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/78546
ISSN
1976-6483
Abstract
This paper demonstrates a calibration methodology for adjusting model parameters and factors using assistant tools ― python and GenOpt. In this study, a building simulation model is developed for a demonstration building for a low-energy solar house. The model is composed of a 3D model describing building architecture and HVAC system model using TRNSYS simulation program. In this study, model calibration methodology consists of two phases in order to improve the accuracy of building energy model and reduce errors of simulation results: Parameter adjustment phase and factor optimization phase. Trial and error approach is used for the first phase and GenOpt tool is employed for the second phase to improve the model performance. Based on American Society of Heating, Refrigerating and Air-conditioning Engineers (ASHRAE) Guideline 14 indices, the performance of the calibrated building simulation model is evaluated to obtain Normalized Mean Bias Error (NMBE)hourly, values within ±10% and Coefficient Variation of Root Mean Square Error (CV (RMSE))hourly, values within 30%. The performance indices are calculated with simulated and measured temperatures of each indoor zone and buffer tank. Daily data is used for calibrating heat pump (HP) electrical energy consumption because it is hard to fit the operating time of HP which can be different to time that heating load occurs. As a result of the calibration process, it is found that the values of NMBEhourly and CV (RMSE)hourly achieves within followings: Average indoor temperature 一 NMBEhourly is 1.2% and CV (RMSE)hourly is 2.2%. Buffer tank temperature NMBEhourly is 1.5% and CV (RMSE)hourly is 8.2%. And the value of NMBEdaily and CV (RMSE)daily are used for HP electrical use as following: NMBEdaily is 9.5%, CV (RMSE) is 23.4%.
Files in This Item
There are no files associated with this item.
Appears in
Collections
공과대학 > 설비·소방공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kong, Minsuk photo

Kong, Minsuk
Engineering (Department of Building Equipment System&Fire Protection Engineering)
Read more

Altmetrics

Total Views & Downloads

BROWSE