Detailed Information

Cited 7 time in webofscience Cited 5 time in scopus
Metadata Downloads

Morphologic Evaluation of Ductus Diverticulum Using Multi-Detector Computed Tomography: Comparison with Traumatic Pseudoaneurysm of the Aortic Isthmus

Authors
Ann, Jun HyungKim, Eun YoungJeong, Yu MiKim, Jeong HoKim, Hyung SikChoi, Hye-Young
Issue Date
Oct-2016
Publisher
KOWSAR PUBL
Keywords
Ductus Diverticulum; Aorta; Thoracic; Tomography; X-ray Computed; Trauma
Citation
IRANIAN JOURNAL OF RADIOLOGY, v.13, no.4
Journal Title
IRANIAN JOURNAL OF RADIOLOGY
Volume
13
Number
4
URI
https://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/7866
DOI
10.5812/iranjradiol.38016
ISSN
1735-1065
Abstract
Objectives: To evaluate morphologic variations at the aortic isthmus with particular attention to ductus diverticulum, a mimicker of traumatic pseudoaneurysm, and to describe differences using Computed Tomography (CT) images. Patients and Methods: From December 2013 to December 2014, patients who underwent a chest CT examination after blunt trauma at our emergency department were included. Aortic isthmus morphologies were evaluated using multiplanar reconstruction (MPR) and maximum intensity projection (MIP) images as follows. Type I -concave contour, type II -convexity without a discrete bulge, or type III -a discrete focal bulge (defined as ductus diverticulum). Results: After excluding 11 cases of traumatic pseudoaneurysm of the aortic isthmus, a total of 432 trauma patients (mean age = 47.1 +/- 19.1 years, number of males = 318) were evaluated for aortic isthmus morphology, and classified as follows; type I (n = 240, 55.6%), type II (n = 157, 36.3%), and type III (n = 35, 8.1%). As compared with traumatic pseudoaneurysm (n = 11), ductus diverticulum had a smaller vertical diameter (5.5 +/- 1.3mmvs. 11.2 +/- 2.7 mm, P < 0.001), a broader base (14.9 +/- 4.1mmvs. 8.8 +/- 4.5 mm, P < 0.001), a smoother margin (97.1% vs. 27.3%, P < 0.001), and formed obtuse angle with the aortic wall. Furthermore, ductus diverticulum was not associated with the presence of a dissection flap or hemomediastinum. Conclusion: Ductus diverticulum, a mimicker of traumatic pseudoaneurysm of the aortic isthmus, is a frequently observed anatomic variant during CT examinations. Familiarity with its CT imaging findings could avoid it being confused with traumatic pseudoaneurysm in blunt trauma patients.
Files in This Item
There are no files associated with this item.
Appears in
Collections
의과대학 > 의학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Jeong Ho photo

Kim, Jeong Ho
College of Medicine (Department of Medicine)
Read more

Altmetrics

Total Views & Downloads

BROWSE