Detailed Information

Cited 1 time in webofscience Cited 2 time in scopus
Metadata Downloads

Development of a voiding diary using urination recognition technology in mobile environmentDevelopment of a voiding diary using urination recognition technology in mobile environment

Other Titles
Development of a voiding diary using urination recognition technology in mobile environment
Authors
박건현김수진조영삼
Issue Date
Dec-2020
Publisher
한국운동재활학회
Keywords
Urination time recognition; Urination management system; Mobile voiding chart
Citation
Journal of exercise rehabilitation, v.16, no.6, pp.529 - 533
Journal Title
Journal of exercise rehabilitation
Volume
16
Number
6
Start Page
529
End Page
533
URI
https://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/79893
DOI
10.12965/jer.2040790.395
ISSN
2288-176X
Abstract
We invented a wearable device that can measure voiding time and frequency by checking a habitual series of characteristic motions among men. This study collected and analyzed urination time data collected smart bands worn by patients to resolve the clinical issues posed by using voiding charts. By developing a smart band-based algorithm for assessing urination time in patients, this study aimed to explore the feasibility of urination management systems. This study aimed to assess urination time based on a patient’s posture and changes in posture. Motion data were obtained from a smart band on the arm. An algorithm that identifies the three stages of urination (forward movement, urination, backward movement) was developed based on data collected from a 3-axis accelerometer and tilt angle data. Therefore, we analyze hidden Markov model (HMM)-based sequential data to determine urination time. Real-time data were acquired from the smart band. For data corresponding to a specific duration, the value of the signals was calculated and then compared with the set analysis model to calculate the time of urination. The final accuracy of the algorithm was calculated based on clinical guidelines for urologists. The experiment showed a high average accuracy of 92.5%, proving the robustness of the proposed algorithm. The proposed urination time recognition technology draws on acceleration data and tilt angle data collected via a smart band; these data were then analyzed using a classifier after applying the HMM method.
Files in This Item
There are no files associated with this item.
Appears in
Collections
ETC > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE