Detailed Information

Cited 2 time in webofscience Cited 2 time in scopus
Metadata Downloads

Compressed-Sensing Technique Combined with Key-Hole Acquisitions for SNR Enhancement

Authors
Kang, Chang-KiKim, Hang-Keun
Issue Date
Aug-2016
Publisher
SPRINGER WIEN
Citation
APPLIED MAGNETIC RESONANCE, v.47, no.8, pp.823 - 834
Journal Title
APPLIED MAGNETIC RESONANCE
Volume
47
Number
8
Start Page
823
End Page
834
URI
https://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/8041
DOI
10.1007/s00723-016-0797-1
ISSN
0937-9347
Abstract
This study proposes a robust method for signal-to-noise ratio (SNR) enhancement necessary for higher spatial resolution imaging in magnetic resonance imaging (MRI) system. The proposed method combines compressed-sensing (CS) technique with key-hole acquisitions. It uses the average of an image acquired by CS and images obtained by key-hole-based acquisitions. This method is called CS averaging with key-hole acquisitions (CSAK). The feasibility of CSAK was evaluated with anthropomorphic phantom studies at 3.0T MRI. SNR and full-width at half-maximum (FWHM) measured from CSAK were compared to those of other methods, such as CS averaging with multiple acquisitions (CSAM), CS averaging with single acquisition (CSAS), conventional data acquisition, and images obtained using Gaussian-smoothing filters. While CSAS required the least scan time, it showed the poorest SNR. CSAM and CSAK showed higher SNR than the conventional data acquisition method with a full k-space. CSAM and CSAK also had spatial resolution performance comparable to that of full k-space-based image. CSAK required the least sampling points. Therefore, it required less scan time than those for CSAM and conventional single full k-space acquisition without averaging. In this study, we found that signal averaging for higher SNR with higher spatial resolution image without increasing the scan time could be achieved by CS-based averaging with key-hole acquisitions. Therefore, the proposed CSAK method could be used for high spatial resolution imaging required for higher SNR in MRI system.
Files in This Item
There are no files associated with this item.
Appears in
Collections
보건과학대학 > 의용생체공학과 > 1. Journal Articles
보건과학대학 > 방사선학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Hang Keun photo

Kim, Hang Keun
College of IT Convergence (의공학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE