Detailed Information

Cited 27 time in webofscience Cited 34 time in scopus
Metadata Downloads

The Measurement of Stiffness for Major Muscles with Shear Wave Elastography and Myoton: A Quantitative Analysis Study

Authors
Lee, YoungjinKim, MinkyoungLee, Haneul
Issue Date
Mar-2021
Publisher
MDPI
Keywords
muscle; myotonometer; quantitative analysis; ultrasound; shear-wave elastography
Citation
DIAGNOSTICS, v.11, no.3
Journal Title
DIAGNOSTICS
Volume
11
Number
3
URI
https://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/80708
DOI
10.3390/diagnostics11030524
ISSN
2075-4418
Abstract
The present study was performed to assess the relationship between hand-held myotonometer MyotonPRO and shear wave elastography (SWE) measurements of lower limb muscle stiffness during resting and active voluntary contraction. Forty healthy young adults, (20 males and 20 females) participated in the study. The stiffness of each subject's rectus femoris (RF), biceps femoris (BF), tibialis anterior (TA), and medial gastrocnemius (MG) was measured repeatedly by MyotonPRO and SWE. Moderate to strong correlations between the two methods' measurements were found for both resting and active voluntary contraction. (r = 0.416-0.669, p < 0.05; r = 0.398-0.594, p < 0.05, respectively). Muscle stiffness at rest was significantly lower compared contraction in all four muscles measured by both methods (p < 0.05). Intra-rater reliabilities were generally lower when measurements were taken during contraction. Additionally, when compared by gender, muscle stiffness measured by MyotonPRO was significantly higher at rest in men compared to women, except for the TA. However, a significant difference was found in TA muscle stiffness by gender when measured with SWE. When muscles were contracted, all muscles showed significantly higher stiffness in men compared to women. There were moderate to good correlations in muscle stiffness between measurements of SWE and MyotonPRO at rest and during active voluntary contraction. Additionally, both instruments showed good intra-rater reliability.
Files in This Item
There are no files associated with this item.
Appears in
Collections
보건과학대학 > 물리치료학과 > 1. Journal Articles
보건과학대학 > 방사선학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Youngjin photo

Lee, Youngjin
Health Science (Dept.of Radiology)
Read more

Altmetrics

Total Views & Downloads

BROWSE