Detailed Information

Cited 7 time in webofscience Cited 9 time in scopus
Metadata Downloads

Fluorescence Based on Surface Plasmon Coupled Emission for Ultrahigh Sensitivity Immunoassay of Cardiac Troponin I

Authors
Tran, Vien ThiJu, Heongkyu
Issue Date
May-2021
Publisher
MDPI
Keywords
Cardiac biomarker; Fluorescence; Lab-on-chip optical biosensor; Surface plasmon coupled emission; Troponin I
Citation
Biomedicines, v.9, no.5
Journal Title
Biomedicines
Volume
9
Number
5
URI
https://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/81119
DOI
10.3390/biomedicines9050448
ISSN
2227-9059
Abstract
This work demonstrates the quantitative assay of cardiac Troponin I (cTnI), one of the key biomarkers for acute cardiovascular diseases (the leading cause of death worldwide) using the fluorescence-based sandwich immune reaction. Surface plasmon coupled emission (SPCE) produced by non-radiative coupling of dye molecules with surface plasmons being excitable via the reverse Kretschmann format is exploited for fluorescence-based sandwich immunoassay for quantitative detection of cTnI. The SPCE fluorescence chip utilizes the gold (2 nm)-silver (50 nm) bimetallic thin film, with which molecules of the dye Alexa 488 (conjugated with detection antibodies) make a near field coupling with the plasmonic film for SPCE. The experimental results find that the SPCE greatly improves the sensitivity via enhancing the fluorescence signal (up to 50-fold) while suppressing the photo-bleaching, permitting markedly enhanced signal-to-noise ratio. The limit of detection of 21.2 ag mL−1 (atto-gram mL−1 ) is obtained, the lowest ever reported to date amid those achieved by optical technologies such as luminescence and label-free optical sensing techniques. The features discovered such as ultrahigh sensitivity may prompt the presented technologies to be applied for early diagnosis of cTnI in blood, particularly for emergency medical centers overloaded with patients with acute myocardial infarction who would suffer from time-delayed diagnosis due to insufficient assay device sensitivity. © 2021 by the authors. Licensee MDPI, Basel, Switzerland.
Files in This Item
There are no files associated with this item.
Appears in
Collections
바이오나노대학 > 나노물리학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Ju, Heong Kyu photo

Ju, Heong Kyu
BioNano Technology (Department of Physics)
Read more

Altmetrics

Total Views & Downloads

BROWSE