Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Multivariate Assessment for Bioequivalence Based on the Correlation of Random Effect

Authors
An, HyungmiShin, Dongseong
Issue Date
Aug-2021
Publisher
DOVE MEDICAL PRESS LTD
Keywords
bioequivalence test; correlated multiple responses; multivariate random effects model; H-likelihood; multivariate HGLM
Citation
DRUG DESIGN DEVELOPMENT AND THERAPY, v.15, pp.3675 - 3683
Journal Title
DRUG DESIGN DEVELOPMENT AND THERAPY
Volume
15
Start Page
3675
End Page
3683
URI
https://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/82058
DOI
10.2147/DDDT.S318576
ISSN
1177-8881
Abstract
Background and Objective: Bioequivalence tests are fundamental step in assessing the equivalence in bioavailability between a test and reference product. In practice, two separate linear mixed models (LMMs) with random subject effects, which have an area under the concentration-time curve (AUC) and the peak concentration (C-max) as the responses, have become the gold standard for evaluating bioequivalence. Recently, Lee et al developed a multivariate hierarchical generalized linear model (HGLM) for several responses that modeled correlations among multivariate responses via correlated random effects. The objective of this study was to apply this multivariate analysis to the bioequivalence test in practice and to compare the performance of multivariate HGLM and separate LMMs. Methods: Three pharmacokinetic datasets, fixed-dose combination (naproxen and esomeprazole), tramadol and fimasartan data were analyzed. We compared the 90% confidence interval (CI) for the geometric mean ratio (GMR) of a test product to a reference product using the multivariate HGLM and two conventional separate LMMs. Results: We found that the 90% CIs for the GMRs of both AUC and C-max from the multivariate HGLM were narrower than those from the separate LMMs: (0.843, 1.152) vs (0.825, 1.177) for Cmax of esomeprazole in fixed-dose combination data; (0.805, 0.931) vs (0.797, 0.941) for C-max in tramadol data; (0.801, 1.501) vs (0.762, 1.578) for C-max and (1.163, 1.332) vs (1.009, 1.341) for AUC in fimasartan data, consistent with the random subject effects from two separate LMMs being highly correlated in the three datasets (correlation coefficient r = 0.883; r = 0.966; r = 0.832). Conclusion: This multivariate HGLM had good performance in the bioequivalence test with multiple endpoints. This method would provide a more reasonable option to reduce the 90% CI by adding correlation parameters and thus an advantage especially in evaluating the bioequivalence of highly variable drugs with broad 90% CIs.
Files in This Item
There are no files associated with this item.
Appears in
Collections
의과대학 > 의예과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Shin, Dong Seong photo

Shin, Dong Seong
College of Medicine (Department of Medicine)
Read more

Altmetrics

Total Views & Downloads

BROWSE