철도차량 보조전원장치의 전압 제어 안정성 증대를 위한 Anti-windup 기법의 적용 및 비교 분석Application and Comparative Analysis of Anti-windup Method for Improving the Stability of Voltage Control of Auxiliary Power Supplies in Railway System
- Other Titles
- Application and Comparative Analysis of Anti-windup Method for Improving the Stability of Voltage Control of Auxiliary Power Supplies in Railway System
- Authors
- 최종용; 이수길; 이준희; 이현재; ⋅손진근
- Issue Date
- Dec-2021
- Publisher
- 대한전기학회
- Keywords
- Anti-windup; Auxiliary Power Supplies; Flyback converter; Integrator windup; PI controller
- Citation
- 전기학회 논문지 P권, v.70, no.4, pp.233 - 239
- Journal Title
- 전기학회 논문지 P권
- Volume
- 70
- Number
- 4
- Start Page
- 233
- End Page
- 239
- URI
- https://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/82893
- ISSN
- 1229-800x
- Abstract
- In this paper, Application and Comparative Analysis of Anti-windup Method for Improving the Stability of Voltage Control of Auxiliary Power Supplies in Railway System. Because it is easy to design, and the structure is simple, there is a problem in the widely used PI controller to occur. Various problems occur, such as response time delay and overshoot due to integrator windup caused by the accumulation of errors in the integral controller. To improve this, various anti-windup methods have been studied.
Among the representative Anti-windup methods, it was checked whether various problems caused by integrator windup could be solved through the conditional integral Anti-windup method and the tracking Anti-windup method and the error control Anti-windup.
After confirming through PSIM simulation before hardware experiment, DC power conversion system was designed and improvements were confirmed.
- Files in This Item
- There are no files associated with this item.
- Appears in
Collections - IT융합대학 > 전기공학과 > 1. Journal Articles
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.