Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

전국의료관련감염감시체계 중환자실 부문 결과 보고: 2019년 7월부터 2020년 6월Korean National Healthcare-associated Infections Surveillance System, Intensive Care Unit Module Report: Summary of Data from July 2019 through June 2020

Other Titles
Korean National Healthcare-associated Infections Surveillance System, Intensive Care Unit Module Report: Summary of Data from July 2019 through June 2020
Authors
김은진곽이경곽선희고수희권오미김의석김진화김태형김택수문희원박선희안진영유소연유현미이상오조난형최평균홍기호이유미이미숙
Issue Date
Dec-2021
Publisher
대한의료관련감염관리학회
Keywords
Korean National Healthcare-associated Infections Surveillance System; KONIS; Intensive care unit; Healthcare-associated infection
Citation
의료관련감염관리, v.26, no.2, pp.115 - 128
Journal Title
의료관련감염관리
Volume
26
Number
2
Start Page
115
End Page
128
URI
https://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/83015
DOI
10.14192/kjicp.2021.26.2.115
ISSN
2508-5999
Abstract
Background: This report presents the annual data of the intensive care unit (ICU) module of the Korean National Healthcare-associated Infections Surveillance System (KONIS) between July 2019 and June 2020. Methods: We performed prospective surveillance of healthcare-associated infections (HAI), including urinary tract infections (UTIs), bloodstream infections (BSIs), and pneumonia (PNEU), at 340 ICUs in 256 hospitals using the KONIS database. HAI and device-associated infection (DAI) rates were calculated as the number of infections per 1,000 patient-days (PD) and device-days (DD), respectively. Device utilization was calculated as the ratio (DUR) of device to patient days. Results: A total of 4,489 HAIs were found during the study period: 1,646 UTIs (1,597 cases were urinary catheter-associated); 1,964 BSIs (1,695 were central line-associated); and 879 PNEUs (470 were ventilator-associated). The rate of urinary catheter-associated UTIs (CAUTI) was 1.26/1,000 DD (95% confidence interval [CI] 1.20-1.32), whereas the urinary catheter utilization ratio was 0.80 (95% CI, 0.799-0.801). The rate of central line-associated BSIs was 2.16/1,000 DD (95% CI 2.06-2.26), whereas the central line utilization ratio was 0.50 (95% CI 0.499-0.501). The rate of ventilator-associated PNEUs was 0.93/1,000 DD (95% CI 0.85-1.02), whereas the ventilator utilization ratio was 0.32 (95% CI 0.319-0.321). Conclusion: The overall DAI rate was similar to that in the previous year. In particular, the device utilization ratios were reduced. Continuous surveillance prevented an increase in the infection rate and led to a decrease in device use. A continuous infection surveillance system can reduce the infection rate.
Files in This Item
There are no files associated with this item.
Appears in
Collections
ETC > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE