Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

장골 검출기를 이용한 장골 검사에서 3D 프린터로 제작한 구리 필터의 유용성 연구A Study on the Usefulness of Copper Filters Made with 3D Printers in Longbone Examination Using Long Length Detector

Other Titles
A Study on the Usefulness of Copper Filters Made with 3D Printers in Longbone Examination Using Long Length Detector
Authors
김우영서현수한봉주윤명성이영진
Issue Date
Dec-2021
Publisher
대한방사선과학회
Keywords
3D 프린터; 구리 필라멘트; 장골; 장골 검출기; 부가필터; 신호 대 잡음비; 대조도 대 잡음비; 3D Printer; Copper filament; Long-bone; Long length detector; Additional filter; SNR; CNR
Citation
방사선기술과학, v.44, no.6, pp.607 - 613
Journal Title
방사선기술과학
Volume
44
Number
6
Start Page
607
End Page
613
URI
https://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/83079
ISSN
2288-3509
Abstract
Long-bone examination is mainly used for inspection of the lower extremities. Recently, a long length detector (FXRD-1751S, VIEWORKS, Korea) with three digital detectors attached has been developed. High energy X-rays are used because pelvic areas require high image quality. In this case, X-rays are transmitted a lot in thin areas such as an ankle, and it is not suitable for diagnosing an image. Therefore, this study use copper filters made with 3D printers to increase image quality in the Long-bone inspection. A copper filter was manufactured in consideration of the overall thickness of the lower part. The experiment was conducted in anterior-posterior (AP) and lateral (LAT) positions, depending on the presence or absence of the filter. 5x5 pixels of region of interest (ROI) were selected from the pelvis, knee, and ankle areas. X-rays were irradiated under the conditions of 70 kVp and 40 mAs for AP, 80 kVp, and 63 mAs for lat when without filters, 90 kVp and 80 mAs for AP, 90 kVp and 100 mAs for lat when with filters. signal to noise ratio(SNR) ratio and contrast to noise (CNR) values were measured 1106.38, 14.34 before applying the filter and 1189.32, 70.43 after the filter. For the knee area, 650.44, 97.61 before applying the filter, and 1013.17, 444.24 after applying the filter. For the ankle area, 206.65, 23.68 before applying the filter and 993.50, 136.11 after applying the filter. In the Long-bone examination, SNR and CNR were greatly measured when the filter was applied, confirmed the availability of using the copper additional filter.
Files in This Item
There are no files associated with this item.
Appears in
Collections
보건과학대학 > 방사선학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Youngjin photo

Lee, Youngjin
Health Science (Dept.of Radiology)
Read more

Altmetrics

Total Views & Downloads

BROWSE