Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Orbital Wall Reconstruction with Osteoconductive Unsintered Hydroxyapatite/Poly L-Lactide

Authors
Wi, Jae MinKim, Yu JeongChi, Mi Jung
Issue Date
Apr-2016
Publisher
KOREAN OPHTHALMOLOGICAL SOC
Keywords
Absorbable implant; Blowout fracture; Orbital wall reconstruction; Osteoconductive implant; Unsintered hydroxyapatite/poly L-lactide
Citation
JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, v.57, no.4, pp.533 - 539
Journal Title
JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY
Volume
57
Number
4
Start Page
533
End Page
539
URI
https://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/8404
DOI
10.3341/jkos.2016.57.4.533
ISSN
0378-6471
Abstract
Purpose: To evaluate the effect of orbital wall reconstruction with absorbable osteoconductive unsintered hydroxyapatite/poly L-lactide by assessment of the orbital volume via orbital computed tomography. Methods: 24 patients who followed up at least 6 months after orbital wall reconstruction with unsintered hydroxyapatite/poly L-lactide were included. Retrospective clinical chart reviews for clinical manifestations and complications were performed, and orbital volume measurements were taken using the Eclipse Treatment Planning System (ver. 13.0, Varian Medical System Inc., Palo Alto, CA, USA) through orbital computed tomography, which were taken before operation, right after operation, and at last follow up. Results: Fourteen patients (58.3%) showed diplopia and extraocular muscle movement limitation preoperatively. Diplopia was resolved at last follow up and extraocular muscle movement limitation was improved at postoperative 6 months for all cases. The mean volumes of the fractured orbit and the unaffected orbit before operation were 23.62 +/- 0.45 cm(3) and 21.95 +/- 1.01 cm(3), respectively (p = 0.003). The mean volumes of the fractured orbit and the unaffected orbit right after operation were 21.65 +/- 0.91 cm(3) and 21.78 +/- 0.83 cm(3), respectively (p = 0.542). The mean volumes of the fractured orbit and the unaffected orbit at last follow up were 21.84 +/- 0.93 cm(3) and 21.81 +/- 0.91 cm(3), respectively (p = 0.889). Conclusions: Absorbable osteoconductive unsintered hydroxyapatite/poly L-lactide was effective for clinical improvement and orbital volume assessment in cases of orbital wall reconstruction and it can be used safely without definite implant related complications.
Files in This Item
There are no files associated with this item.
Appears in
Collections
의과대학 > 의학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.