Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

The impact of improved non-local means denoising algorithm on photon-counting X-ray images using various Al additive filtrations

Authors
Lee, SeungwanLee, Youngjin
Issue Date
Mar-2022
Publisher
Elsevier
Keywords
Al filtration; Denoising algorithm; Improved non-local means (INLM) approach; Photon-counting X-ray imaging; Quantitative evaluation of image quality
Citation
Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, v.1027
Journal Title
Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Volume
1027
URI
https://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/84222
DOI
10.1016/j.nima.2021.166244
ISSN
0168-9002
Abstract
The filters used in X-ray systems affect the image quality and radiation dose. Although using filters has advantages in terms of image quality and dose, image noise increases because the amount of X-rays in the energy range of the entire area is reduced. Thus, a newly improved non-local means (INLM) denoising algorithm was modeled and applied to X-ray images based on the thickness of the aluminum (Al) filter, which is most commonly used in X-ray imaging systems, to prove its potential use. For X-ray image acquisition, a high-performance cadmium telluride material-based detector and a tube containing Al filters (1-, 3-, and 5-mm thickness) were designed. The proposed INLM denoising algorithm was modeled by including the improved weights for the gradient information for each pixel in the conventional NLM-based equation. When the proposed INLM denoising algorithm was applied to the acquired photon-counting X-ray images, results showed superior performance for both noise characteristics and no-reference-based image evaluation. In particular, we confirmed that when the INLM was applied to X-ray images using 5 mm Al thickness, noise characteristics and no-reference-based evaluation results were improved by approximately 1.36 times and 1.06 times, respectively, compared to the conventional NLM. The study proved that choosing the INLM in photon-counting X-ray images using 5 mm-thick Al filtration is vital for the success of image processing applications. © 2021 Elsevier B.V.
Files in This Item
There are no files associated with this item.
Appears in
Collections
보건과학대학 > 방사선학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Youngjin photo

Lee, Youngjin
Health Science (Dept.of Radiology)
Read more

Altmetrics

Total Views & Downloads

BROWSE