Detailed Information

Cited 2 time in webofscience Cited 2 time in scopus
Metadata Downloads

Osstem Cardiotec Centum Stent Versus Xience Alpine Stent for De Novo Coronary Artery Lesion: A Multicenter, Randomized, Parallel-Designed, Single Blind Test

Authors
Yoon, Chang-HwanJang, JihongHur, Seung HoLee, Jun-HeeHan, Seung HwanHong, Soon-JunChang, KiyukChae, In-Ho
Issue Date
May-2022
Publisher
Korean Society of Circulation
Keywords
Coronary disease; Coronary restenosis; Drug-eluting stents; Percutaneous coronary intervention
Citation
Korean Circulation Journal, v.52, no.5, pp.354 - 364
Journal Title
Korean Circulation Journal
Volume
52
Number
5
Start Page
354
End Page
364
URI
https://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/84389
DOI
10.4070/KCJ.2021.0198
ISSN
1738-5520
Abstract
Background and objectives: To compare the safety and efficacy of a new everolimus-eluting stent with an abluminal-coated biodegradable polymer (Osstem Cardiotec Centum) with those of the Xience Alpine stent (Xience). Methods: This randomized, prospective, multicenter, parallel-designed, single-blind trial was conducted among patients with myocardial ischemia undergoing percutaneous coronary intervention (PCI) from 21st September 2018 until 3rd July 2020. The primary efficacy endpoint was in-segment late lumen loss (LLL) at 270 days after the procedure and the primary safety endpoints were major adverse cardiac events (MACE), composite of cardiac death, myocardial infarction, and target lesion revascularization. Results: We enrolled 121 patients and analyzed 113 patients who finished 270 days of followup for the primary efficacy endpoint. The mean age of the participants was 66.8 years. As for the primary efficacy endpoint, LLL of the Osstem Cardiotec Centum group was 0.09±0.13 mm and that of the Xience group was 0.12±0.14 mm (upper limit of 1-sided 95% confidence interval, 0.02; p for non-inferiority, 0.0084). This result demonstrates the non-inferiority of the Osstem Cardiotec Centum. As for the primary safety endpoint, MACE occurred in one patient (1.59% of the Xience group). Meanwhile, no MACE occurred in the Osstem Cardiotec Centum group. Conclusions: The Osstem Cardiotec Centum is non-inferior to the Xience Alpine® stent and is confirmed to be safe. It could be safely and effectively applied to patients with coronary artery disease undergoing PCI. Copyright © 2022.
Files in This Item
There are no files associated with this item.
Appears in
Collections
의과대학 > 의학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Han, Seung Hwan photo

Han, Seung Hwan
College of Medicine (Department of Medicine)
Read more

Altmetrics

Total Views & Downloads

BROWSE