Detailed Information

Cited 1 time in webofscience Cited 1 time in scopus
Metadata Downloads

Customized Radiofrequency Phased-Array Coil Combining Transmit-Only, Receive-Only, and Transmit/Receive Coils for Magnetic Resonance Imaging of Visual Cortex at 7 Teslaopen access

Authors
Kim, Hyeong-SeopSong, Byung-PanKim, RoyoungChoi, Woo-ChulKim, DonghyukShim, Won MokKim, Kyoung-NamLee, Seung-Kyun
Issue Date
Apr-2022
Publisher
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
Keywords
Visual cortex; RF coil; TORO coil; combined TRx coil; magnetic resonance imaging; functional MRI
Citation
IEEE ACCESS, v.10, pp.42083 - 42093
Journal Title
IEEE ACCESS
Volume
10
Start Page
42083
End Page
42093
URI
https://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/84424
DOI
10.1109/ACCESS.2022.3167422
ISSN
2169-3536
Abstract
Magnetic resonance imaging (MRI) using an ultra-high magnetic field (7 Tesla) enables detailed and non-invasive studies of the function and anatomy of the human visual cortex, which is the brain region responsible for visual signal processing. However, 7T human MRI often suffers from image shading in the occipital region due to the radiofrequency (RF) wave propagation effect. Dedicated visual cortex coils, on the other hand, often lack the capability to visualize the whole brain which is necessary for image registration. We propose a novel RF coil structure in which a 2-channel transmit and receive (TRx) coil is grafted onto the frontal part of a multi-channel transmit-only/receive-only (TORO, 4Tx/14Rx) visual cortex coil. This coil was tested for high-resolution functional MRI with an in-plane resolution of 0.5 mm. The results showed that the proposed coil achieved a higher (x2.5) temporal signal-to-noise ratio (tSNR) in functional imaging of the visual cortex area than that of a commercial 7T whole-head coil. The added 2-channel TRx elements allowed whole-brain edge images to be acquired, enabling successful brain segmentation and atlas registration without the need for a second scan using a whole-head coil. The proposed coil structure can be useful for high-resolution visual functional MRI at very high magnetic fields due to its sensitivity, open geometry, and compatibility with the standard image processing workflow.
Files in This Item
There are no files associated with this item.
Appears in
Collections
보건과학대학 > 의용생체공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Kyoung Nam photo

Kim, Kyoung Nam
College of IT Convergence (의공학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE