Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Attribution of the rise in radiation dose to the relaxed panoramic radiography diagnostic reference level in Korea

Authors
Han, S.J.Kim, S.
Issue Date
Jan-2022
Publisher
IJRR-IRANIAN JOURNAL RADIATION RES
Keywords
Dental panoramic radiographic; Diagnostic reference level; Dose area product; Public health; Radiation dose
Citation
International Journal of Radiation Research, v.20, no.1, pp.249 - 252
Journal Title
International Journal of Radiation Research
Volume
20
Number
1
Start Page
249
End Page
252
URI
https://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/84801
DOI
10.52547/ijrr.20.1.39
ISSN
2322-3243
Abstract
Background: In Korea, the adoption of dental panoramic radiography devices is steadily growing, and diagnostic reference level (DRL) continues to increase in parallel with this phenomenon relative to that in other countries. Moreover, radiation dose is a risk factor for public health; however, to our knowledge, no study has investigated the cause of this rise in DRL. This study therefore sought to discern why the proposed DRL is high by measuring the use status and the dose area product (DAP) of panoramic devices. Materials and Methods: DAP was measured under standard adult exposure conditions to 41 panoramic devices in use at dental clinics in Incheon, and the differences between the groups were analyzed by stratifying them into below-the-DRL group and exceeding-the-DRL group. Results: Ultimately, the most significant cause of the increase in DRL in dental panoramic radiography was that patients were irradiated by the system in a high-definition mode using high tube voltage or were subjected to long exposure time. Conclusions: To protect public health from excessive radiation dose, dentists or radiologists must attempt to use the lowest possible radiation dose according to the “as low as reasonably achievable” principle while ensuring that sufficient image quality is attained for diagnostic and treatment purposes. In addition, the Korea Disease Control and Prevention Agency needs to revise the current DRL, which is a third quartile value of the measured dose distribution, to an appropriate value by referring to the opinions of expert groups. © 2022 Novin Medical Radiation Institute. All rights reserved.
Files in This Item
There are no files associated with this item.
Appears in
Collections
보건과학대학 > 방사선학과 > 1. Journal Articles
보건과학대학 > 치위생학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Sung Chul photo

Kim, Sung Chul
Health Science (Dept.of Radiology)
Read more

Altmetrics

Total Views & Downloads

BROWSE