Detailed Information

Cited 3 time in webofscience Cited 3 time in scopus
Metadata Downloads

Application feasibility of median modified Wiener filter (MMWF) algorithm for customized breast ACR phantom images using 3D printing technology in mammography

Authors
Park, ChanrokLee, Youngjin
Issue Date
May-2022
Publisher
Elsevier
Keywords
3D printing technology; Breast American college of radiology (ACR) phantom; Mammography; Median modified Wiener filter; Noise reduction algorithm
Citation
Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, v.1031
Journal Title
Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Volume
1031
URI
https://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/84861
DOI
10.1016/j.nima.2022.166570
ISSN
0168-9002
Abstract
The median modified Wiener filter (MMWF) algorithm, which is a combination of median and Wiener filters, was applied to reduce the noise signal contained in digital image systems. In this study, we investigated the effect of MMWF algorithm with mask sizes of 3 × 3, 5 × 5, 7 × 7, and 9 × 9 and compared it to the median and Wiener filters with a breast American College of Radiology (ACR) phantom designed using 3D printing technology. To compare the similarity between the conventional and 3D printed breast ACR phantoms at various tube voltages and tube currents, the peak signal-to-noise (PSNR) ratio was recorded. Then, the noise level of the mammographic X-ray image applied with the MMWF algorithm using various mask sizes and the conventional filtering methods were compared and evaluated. According to the results, when the MMWF algorithm using a mask size of 9 × 9 was applied to the X-ray phantom image, superior signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and coefficient of variation (COV) values were derived. In addition, by comparing the average values obtained using the conventional noise reduction methods, we confirmed that the SNR, CNR, and COV values obtained from the MMWF algorithm, using a 9 × 9 mask size, improved by 1.91, 2.29, and 4.77 times, respectively. In conclusion, applicability of the mammographic X-ray field after ACR phantom production using 3D printing technology was proven in this study. An optimal mask size of 9 × 9 for the MMWF algorithm was proposed for improving the image quality of the acquired image. © 2022 Elsevier B.V.
Files in This Item
There are no files associated with this item.
Appears in
Collections
보건과학대학 > 방사선학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Youngjin photo

Lee, Youngjin
Health Science (Dept.of Radiology)
Read more

Altmetrics

Total Views & Downloads

BROWSE