Coupling Effect Suppressed Compact Surgical Robot with 7-Axis Multi-Joint Using Wire-Driven Methodopen access

Authors
Yoon, KicheolCho, Sung-MinKim, Kwang Gi
Issue Date
May-2022
Publisher
MDPI
Keywords
7-axis joint; surgical robot; wire-driven method; coupling effect; forward kinematics
Citation
MATHEMATICS, v.10, no.10
Journal Title
MATHEMATICS
Volume
10
Number
10
URI
https://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/85027
DOI
10.3390/math10101698
ISSN
2227-7390
Abstract
Currently, the most prevalent surgical treatment method is laparoscopic surgery. Robotic surgery has many advantages over laparoscopic surgery. Therefore, robotic surgery technology is currently constantly evolving. The advantages of robotic surgery are that it can minimize incision, bleeding, and sequelae. Other advantages of robotic surgery are that it can reduce hospitalization, recovery period, and side effects. The appeal of robotic surgery is that it requires fewer surgical personnel compared to laparoscopic surgery. This paper proposes an ultra-compact 7-axis vertical multi-joint robot that employs the wire-driven method for minimally invasive surgery. The proposed robot analyzes the degree of freedom and motion coupling for control. The robot joint is composed of a total of seven joints, and among them, the 7-axis joint operates the forceps. At this time, the forceps joint (#7 axis) can only operate open and close functions, while the link is bent and rotatable, regardless of position change. This phenomenon can be analyzed by Forward Kinematics. Also, when the DOF rotates, the passing wires become twisted, and the wire is generated through length change and coupling phenomenon. The maximum rotation angle of DOF is 90 degrees and the rotating passing wire is wound by the rotation of the wire pulley. If the DOF is rotated to the full range of 120 degrees, the second DOF will be rotated to 90 degrees, and at this time, the coupling phenomenon caused by the first DOF rotation can be eliminated. The length change and the robot joint angle change related to the motor drive, based on the surgical robot control using the wire-driven method, are correlated, and the values for the position and direction of the end effector of the robot can be obtained through a forward kinematic analysis. The coupling problem occurring in the wire connecting the robot driving part can be solved through a kinematic analysis. Therefore, it was possible to test the position of the slave robot and the performance of the surgical forceps movement using the master system.
Files in This Item
There are no files associated with this item.
Appears in
Collections
보건과학대학 > 의용생체공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Kwang Gi photo

Kim, Kwang Gi
College of IT Convergence (의공학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE