Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Design of Rotated Surface Coil Array for Multiple-Subject Imaging at 400 MHzopen access

Authors
Nam, TaewooKim, DonghyukSeo, MinyeongIm, GeunhoHernandez, DanielLee, TaekwanKim, Kyoung-Nam
Issue Date
Jun-2022
Publisher
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
Keywords
Rotated surface coil; rotation angle; magnetic resonance imaging; multiple-subject; phenotyping; radio frequency coil; uniformity
Citation
IEEE ACCESS, v.10, pp.66281 - 66289
Journal Title
IEEE ACCESS
Volume
10
Start Page
66281
End Page
66289
URI
https://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/85256
DOI
10.1109/ACCESS.2022.3183119
ISSN
2169-3536
Abstract
Multiple-subject magnetic resonance imaging has been used in phenotyping studies to reduce the total experimental time by simultaneously capturing images of multiple animals using single or multiple radio frequency (RF) coils. However, conventional methods must consider decoupling circuits to minimize the mutual inductance coupling between RF coils. These decoupling circuits unnecessarily increase the field of view and image acquisition times. In this study, we propose a rotated surface (RS) coil that can generate a uniformly transmitted magnetic field (vertical bar B-1(+)vertical bar) and minimize the distance between coils when used for multiple-animal imaging without decoupling circuits. The RS coil was designed using an electromagnetic (EM) simulation software, and the rotation angle, which creates a uniform vertical bar B-1(+)vertical bar-component, was derived by mathematical calculations. We compared the vertical bar B-1(+)vertical bar-component uniformity produced by RS coils with different rotation angles and a 4-leg high-pass filter birdcage coil in multiple-coil arrays at the same location using EM simulations. The RS coil displayed a uniformity greater than 94% and 84% uniformity when used as a single-channel and multiple-coil array in the central axial plane, respectively. Following the EM simulations, a multiple-mice RS coil array was manufactured, and a bench test was performed to ensure its operation at 400 MHz and for coupling analysis. T1-FLASH images of the four phantoms and mice were acquired using a multiple RS coil array in a 9.4-T preclinical MR system. The signal-to-noise ratio and uniformity were measured using the phantom images.
Files in This Item
There are no files associated with this item.
Appears in
Collections
보건과학대학 > 의용생체공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Kyoung Nam photo

Kim, Kyoung Nam
College of IT Convergence (의공학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE