Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Low-dose abdominopelvic computed tomography in patients with lymphoma: An image quality and radiation dose reduction studyopen access

Authors
Yoon, SungjinYoo, Kwai HanPark, So HyunKim, HawkLee, Jae HoonPark, JinnyPark, Seong HoKim, Hwa Jung
Issue Date
Aug-2022
Publisher
Public Library of Science
Citation
PLoS ONE, v.17, no.8
Journal Title
PLoS ONE
Volume
17
Number
8
URI
https://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/87515
DOI
10.1371/journal.pone.0272356
ISSN
1932-6203
Abstract
This study aimed to evaluate image quality, the detection rate of enlarged lymph nodes, and radiation dose exposure of ultralow-dose and low-dose abdominopelvic computed tomography (CT) in patients with lymphoma. Patients with lymphoma who underwent abdominopelvic CT using dual-source scanner were retrospectively recruited from a single center. CT images were obtained at 90 kVp dual-source mode reformatted in three data sets using the advanced modelled iterative reconstruction algorithm: 100% (standard-dose CT), 66.7% (low-dose CT), and 33.3% (ultralow-dose CT). Two radiologists analyzed subjective image quality and detection of abdominal enlarged lymph nodes on ultralow-dose, low-dose, and standard-dose CT blindly and independently. The results were compared with reference standards. Three readers (two radiologists and one hematologist) reviewed overall image quality and spleen size. In total, 128 consecutive CT scans (77 complete response, 44 partial response, 6 progressive disease, and 1 initial evaluation) from 86 patients (64 B-cell lymphoma, 14 T/NK-cell lymphoma, and 8 Hodgkin’s lymphoma cases) were assessed. The enlarged lymph node-based detection rates for two readers were 97.0% (96/99) and 94.0% (93/99) on standard-dose CT, 97.0% (96/99) and 94.0% (93/99) on low-dose CT, and 94.0% (93/99) and 89.9% (89/99) on ultralow-dose CT. Overall image quality was 3.8 ± 0.5, 3.9 ± 0.5, and 4.1 ± 0.5 on ultralow-dose CT; 4.7 ± 0.4, 4.6 ± 0.5, and 4.8 ± 0.3 on low-dose CT; and 4.8 ± 0.4, 4.7 ± 0.4, and 4.9 ± 0.2 on standard-dose CT, according to two radiologists and one hematologist, respectively. Intraclass correlation coefficients of spleen size were 0.90 (95% confidence interval [CI], 0.87–0.93), 0.91 (95% CI, 0.88–0.93), and 0.91 (95% CI, 0.88–0.93) on ultra-low-dose, low-dose, and standard-dose CT, respectively. Mean effective radiation doses of standard-dose, low-dose, and ultralow-dose CT were 5.7 ±1.8 mSv, 3.8 ± 1.2 mSv, and 1.9 ± 0.6 mSv, respectively. Our findings suggest that ultralow-dose and low-dose CT, even with radiation doses reduced by 66.7% and 33.3%, respectively, maintained adequate image quality. These imaging modalities may be employed for follow-up lymphoma evaluation in consideration of the long surveillance periods. Copyright: © 2022 Yoon et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
Files in This Item
There are no files associated with this item.
Appears in
Collections
의과대학 > 의학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Yoo, Kwai Han photo

Yoo, Kwai Han
College of Medicine (Department of Medicine)
Read more

Altmetrics

Total Views & Downloads

BROWSE