Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Spatial resolution and natural image quality assessment evaluation of gamma camera image using pinhole collimator in lutetium-yttrium oxyorthosilicate scintillation detectoropen access

Authors
Kim, KyuseokLee, Youngjin
Issue Date
Jul-2023
Publisher
KOREAN NUCLEAR SOC
Keywords
Gamma camera imaging; Pinhole collimator; Lutetium-yttrium oxyorthosilicate (LYSO) scintillation detector; Spatial resolution evaluations
Citation
NUCLEAR ENGINEERING AND TECHNOLOGY, v.55, no.7, pp.2567 - 2571
Journal Title
NUCLEAR ENGINEERING AND TECHNOLOGY
Volume
55
Number
7
Start Page
2567
End Page
2571
URI
https://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/88482
DOI
10.1016/j.net.2023.04.027
ISSN
1738-5733
Abstract
Scintillator materials are widely used in the medical and industrial fields for imaging systems using gamma cameras. In this study, image evaluation is performed by modeling a gamma camera system based on a lutetium-yttrium oxyorthosilicate (LYSO) scintillation detector using a pinhole collimator that can improve the spatial resolution. A LYSO detector-based gamma camera system is modeled using a Monte Carlo simulation tool. The geometric concept of the pinhole collimator is designed using various magnification factors, and the spatial resolution is measured using the acquired source image. To eval-uate the resolution, the full width at half maximum (FWHM) and natural image quality assessment (NIQE), a no-reference-based parameter, are used. We confirm that the FWHM and NIQE values decrease simultaneously when the diameter of the pinhole collimator increases. Additionally, we confirm that the spatial resolution improves as the magnification factor increases under the same pinhole diameter condition. Particularly, a 0.57 mm FWHM value is obtained using the modeled gamma camera system with a LYSO scintillation detector. In conclusion, our results demonstrate that a pinhole collimator with a LYSO scintillation detector is a promising gamma camera imaging system.& COPY; 2023 Korean Nuclear Society, Published by Elsevier Korea LLC. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
Files in This Item
There are no files associated with this item.
Appears in
Collections
보건과학대학 > 방사선학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Youngjin photo

Lee, Youngjin
Health Science (Dept.of Radiology)
Read more

Altmetrics

Total Views & Downloads

BROWSE