Abstract
The authors have studied hydraulic design of reactor coolant pump used for small modular reactor. Computational fluid dynamics was used to evaluate the impeller design. Seven factors for the 3D shape variables of the Impeller were selected as a design variables. As a result of using the response surface method for optimizing the shape of the impeller, we were able to select four major design factors for efficiency. The four factors were the impeller blade lengths, outlet blade angle component, and rake component. Finally, we obtained an efficient impeller design through the optimization of these four factors. The head increasing was 0.4m and the efficiency was improved by 0.5% compared to the original model.
Files in This Item
There are no files associated with this item.
Appears in
Collections
공과대학 > 기계공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Jeong, Jae Ho photo

Jeong, Jae Ho
Engineering (기계·스마트·산업공학부(기계공학전공))
Read more

Altmetrics

Total Views & Downloads

BROWSE