Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Monte Carlo simulation study of performance evaluation for sensitivity and scatter fraction in gamma camera scintigraphy with TlBr pixelated semiconductor detector with different parallel-hole collimator designs

Authors
Park, ChanrokLee, Youngjin
Issue Date
Mar-2023
Publisher
Elsevier
Keywords
Gamma camera scintigraphy; Geant4 application for tomographic emission (GATE) simulation; Parallel-hole collimator; Sensitivity and scatter fraction evaluations; Thallium bromide (tlBr) semiconductor
Citation
Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, v.1048
Journal Title
Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Volume
1048
URI
https://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/89639
DOI
10.1016/j.nima.2022.167884
ISSN
0168-9002
1872-9576
Abstract
Thallium bromide (TlBr) semiconductor materials are widely used to detect gamma rays. They have excellent detection efficiency owing to their high stopping and effective atomic number. The purpose of this study was to compare image quality using TlBr and conventional detector materials according to parallel-hole collimator geometry in gamma camera scintigraphy. The Geant4 application for tomographic emission (GATE) simulation tool was used. Cadmium telluride (CdTe), cadmium zinc telluride (CZT), and TlBr semiconductor materials were used; the parallel-hole collimator lengths were designed as 0.4, 0.6, 0.8, and 1.0 cm. For qualitative analysis, images were acquired using a quadrant-bar phantom with different bar thicknesses. Quantitative analyses, such as sensitivity (cps/MBq) and scatter fraction using a point source with 99mTc of 1 mCi, were conducted. The sensitivity with TlBr material with collimator lengths of 0.4, 0.6, 0.8, and 1.0 cm was 2.38, 2.39, 2.39, and 2.36 times greater than with CdTe and CZT materials, and the scatter fraction with TlBr material was 1.26, 1.25, 1.24, and 1.31 times less than the scatter fraction with CdTe and CZT materials with the same collimator length, respectively. There was no significant difference in sensitivity and scatter fraction between CdTe and CZT materials. Thus, we confirmed that TlBr is a potential detector material with improved sensitivity and scatter fraction in gamma camera scintigraphy. © 2022 Elsevier B.V.
Files in This Item
There are no files associated with this item.
Appears in
Collections
ETC > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Youngjin photo

Lee, Youngjin
Health Science (Dept.of Radiology)
Read more

Altmetrics

Total Views & Downloads

BROWSE