Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Long-term performance evaluation of liquid-based photovoltaic thermal (PVT) modules with overheating-prevention technique

Authors
Joo, Hong-JinAn, Young-SubKim, Min-HwiKong, Minsuk
Issue Date
Nov-2023
Publisher
PERGAMON-ELSEVIER SCIENCE LTD
Keywords
Photovoltaic thermal; Overheating prevention; Thermal efficiency; Electrical efficiency; Performance ratio; Long-term tests
Citation
ENERGY CONVERSION AND MANAGEMENT, v.296
Journal Title
ENERGY CONVERSION AND MANAGEMENT
Volume
296
URI
https://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/90580
DOI
10.1016/j.enconman.2023.117682
ISSN
0196-8904
1879-2227
Abstract
Laboratory and long-term field tests were conducted to evaluate the overall performance and building applicability of liquid-based photovoltaic thermal (PVT) modules with overheating-prevention techniques in buildings. Three types of flat PVT modules were designed and manufactured: the glazed PVT module with a transparent film covering the photovoltaic (PV) cells, glazed PVT module with a glass covering the PV cells, and unglazed PVT module with a glass covering the PV cells. Based on the thermal and electrical performance results, the glazed PVT module with a transparent film covering the PV cells exhibited a maximum overall efficiency of approximately 71.1%. This could be attributed to less heat losses induced by glazing and less reflectivity caused by film covering the PV cells. Less reflectivity and greater cooling allowed the unglazed PVT module to have the higher electrical efficiency. Thirteen glazed PVT modules with overheating-prevention techniques were installed on the roof of a residential building and field tested for one year. The roof-integrated PVT system with an average overall efficiency of 27.4% produced 8,187.1 kWh heat and 4,430.1 kWh electricity. In terms of electricity performance evaluation, the monthly average performance ratio (PR) ranged from 55.4% to 63.2%, which was lower than that of conventional building-integrated photovoltaic module because of the lower transmittance induced by glazing, greater PV panel temperature caused by glazing and high temperature of working fluid, and low incoming solar irradiation owing to shading. The overheating-prevention device operated well, and no overheating-related failure occurred during field testing.
Files in This Item
There are no files associated with this item.
Appears in
Collections
ETC > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kong, Minsuk photo

Kong, Minsuk
Engineering (Department of Building Equipment System&Fire Protection Engineering)
Read more

Altmetrics

Total Views & Downloads

BROWSE