Label-free electrochemical impedimetric immunosensor for sensitive detection of IgM rheumatoid factor in human serum

Authors
Chinnadayyala, Somasekhar R.Park, JinsooAbbasi, Muhammad A.Choa, Sungbo
Issue Date
15-Oct-2019
Publisher
ELSEVIER ADVANCED TECHNOLOGY
Keywords
Interdigitated wave type microelectrode array; Self-assembled monolayers; IgM rheumatoid factor; Atomic force microscopy; Electrochemical impedance spectroscopy
Citation
BIOSENSORS & BIOELECTRONICS, v.143
Journal Title
BIOSENSORS & BIOELECTRONICS
Volume
143
URI
https://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/912
DOI
10.1016/j.bios.2019.111642
ISSN
0956-5663
Abstract
The authors report a label-free and direct detection of rheumatoid factor- Immunoglobulin M (IgM-RF) based on an impedimetric-interdigitated wave type microelectrode array (IDW mu E). IDW mu E was functionalized with a self-assembled monolayer (SAM) of thioctic acid for antigen immobilization. The SAM functionalized IDW mu E were characterized by atomic force microscopy, Energy Dispersive X-Ray Spectroscopy, and X-ray photoelectron spectroscopy. The covalent immobilization of IgG-Fc onto the SAM modified electrode arrays was characterized morphologically via AFM and electrochemically via cyclic voltammetry and electrochemical impedance spectroscopy. Impedimetric measurements in the presence of redox probe (Potassium ferrocyanide and potassium ferricyanide) showed a significant change in both the impedance spectrum and charge transfer resistance upon IgM-RF binding. Impedance measurements were target specific and linear with an increase in IgM-RF concentrations between 1 and 200 IU mL(-1) in redox probe and human serum, respectively. The sensor showed detection limits of 0.6 IU mL(-1) in the presence of redox probe and 0.22 IU mL(-1) in the human serum. The biosensor exhibited good reproducibility (relative standard deviation (RSD), 4.96%) and repeatability (RSD, 2.31%) with an acceptable selectivity towards IgM-RF detection. The sensor also showed a good stability for 3 weeks at 4 degrees C in 1X PBS. Therefore, the sensitive and stable immunosensor exhibiting IDW mu E features can be integrated with a miniaturized potentiostat to develop a sensing system that detects IgM-RF for point-of-care applications.
Files in This Item
There are no files associated with this item.
Appears in
Collections
IT융합대학 > 전자공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Somasekhar, Reddy Chinnadayyala photo

Somasekhar, Reddy Chinnadayyala
IT (Department of Electronic Engineering)
Read more

Altmetrics

Total Views & Downloads

BROWSE