Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Development of a New Liquid Type Rapid Urease Test Kit (Helicotest (R)): Comparison with Other Commercial Kitsopen access새로운 액체형 신속 요소 분해 검사 키트의 개발(Helicotest®): 상용화된 검사 키트와의 비교

Other Titles
새로운 액체형 신속 요소 분해 검사 키트의 개발(Helicotest®): 상용화된 검사 키트와의 비교
Authors
Lee, HannahHwang, Hyo SangChung, Jun-WonKim, Kyeong AhKim, Seon Tae
Issue Date
May-2023
Publisher
Korean Soc Gastroenterology
Keywords
Helicobacter pylori; Diagnostic test kit
Citation
KOREAN JOURNAL OF GASTROENTEROLOGY, v.81, no.5, pp 209 - 215
Pages
7
Journal Title
KOREAN JOURNAL OF GASTROENTEROLOGY
Volume
81
Number
5
Start Page
209
End Page
215
URI
https://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/91982
DOI
10.4166/kjg.2022.139
ISSN
1598-9992
2233-6869
Abstract
Background/Aims: A quick and accurate diagnosis of Helicobacter pylori (H. pylori) infections is vital for effectively managing many upper gastrointestinal tract diseases. Many diagnostic methods have been developed for rapid and accurate diagnosis, including invasive and non-invasive methods, but each tool has some limitations. Among the invasive diagnostic methods, the rapid urease test (RUT) is a relatively time-saving and accurate method, but a variation in the reaction time range causes inconvenience and inefficiency in the clinical field. This study developed a liquid-type medium, Helicotest (R), to enable faster detection. This study examined the reaction time of a new liquid-type RUT kit with other commercial kits. Methods: Two H. pylori strains were cultured (H. pylori ATCC 700392 and 43504), and the urease activity of H. pylori was measured using a urease activity assay kit (MAK120, Sigma Aldrich). Four RUT kits were used to compare the time of H. pylori detection, including Helicotest (R) (Won Medical, Bucheon, Korea), Hp kit (Chong Kun Dang, Seoul, Korea), CLO kit (Halyard, Alpharetta, GA, USA), and ASAN Helicobacter Test (R) (ASAN, Seoul, Korea). Results: The detection of H. pylori was possible in bacterial amounts less than 10 mu L. The color change was detected from five minutes with bacterial densities of 5 mu L and 10 mu L for both strains, whereas 30 minutes and one hour were required for 0.5 mu L and a 1 mu L bacterial density of ATCC 43504 and 700392 strains, respectively. Conclusions: Compared to other RUT kits, Helicotest (R) showed the fastest reaction. Therefore, faster diagnosis in clinical practice is expected.
Files in This Item
There are no files associated with this item.
Appears in
Collections
ETC > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Chung, Jun-Won photo

Chung, Jun-Won
College of Medicine (Department of Medicine)
Read more

Altmetrics

Total Views & Downloads

BROWSE