Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

대퇴전자간 골절 정복에 있어 관상면상의 부정 정렬 평가 방법으로서 수술 중 Greater Trochanter Orthogonal Line의 유용성Assessment of Coronal Plane Malalignment Following Reduction of Trochanteric Fractures-Simple Intraoperative Guideline Using Greater Trochanter Orthogonal Line

Other Titles
Assessment of Coronal Plane Malalignment Following Reduction of Trochanteric Fractures-Simple Intraoperative Guideline Using Greater Trochanter Orthogonal Line
Authors
윤용철Jong-Keon OhWon-Yong ShonHan-Ju KimJae-Woo Cho
Issue Date
2016
Publisher
대한골절학회
Keywords
Hip fractures; Reduction; Trochanter center distance; GT orthogonal line
Citation
대한골절학회지, v.29, no.1, pp.1 - 11
Journal Title
대한골절학회지
Volume
29
Number
1
Start Page
1
End Page
11
URI
https://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/9644
ISSN
1225-1682
Abstract
Purpose: There is no consensus on a clear intraoperative guideline for judging the coronal plane alignment following reduction of trochanteric fractures. Complex angular measurements using fluoroscope monitors are tedious. Therefore the relation of the horizontal line from the tip of the greater trochanter (GT orthogonal) and femur head center (HC orthogonal) was studied to define this line as a criterion for predicting varus-valgus malalignment.Materials and Methods: We studied this relation in 200 standing orthoradiograms which included 100 males and 100 females. The images were digitally analyzed using the picture archiving and communication system. GT orthogonal line and HC orthogo-nal line were evaluated. The distance of these lines was measured as trochanter center distance (TCD) and its correlation with angular parameters like neck shaft angle, medial proximal femoral angle with reference to anatomical axis (aMPFA) and lateral proximal femoral angle with reference to mechanical axis (mLPFA) were analyzed.Results: In all patients, the GT orthogonal line passed either at or above the center of the head. Overall mean of TCD was 7.22 mm, ranging from 0 to 17.57 mm. TCD was found to show strong correlation with angular parameters like aMPFA, mLPFA and neck shaft angle. TCD was less than one fourth of the corresponding head diameter in around 90%. Therefore following reduc-tion of trochanteric fractures, the GT orthogonal line should pass through the superior juxta central quadrant of the femoral head.Conclusion: This line can be represented by a guide wire with fluoroscopy during surgery. The GT orthogonal line can be used intraoperatively as a simplified tool for prediction of varus/valgus malalignment following the reduction of trochanteric fractures.
Files in This Item
There are no files associated with this item.
Appears in
Collections
의과대학 > 의학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Yoon, Yong Cheol photo

Yoon, Yong Cheol
College of Medicine (Department of Medicine)
Read more

Altmetrics

Total Views & Downloads

BROWSE