Detailed Information

Cited 5 time in webofscience Cited 5 time in scopus
Metadata Downloads

Microvascular Imaging Using Compressed Sensing at 7T MRI: A Preliminary Study

Authors
Park, Chan-AKang, DaehunSon, Young-DonKim, Hang-KeunKang, Chang-Ki
Issue Date
Nov-2015
Publisher
SPRINGER WIEN
Citation
APPLIED MAGNETIC RESONANCE, v.46, no.11, pp.1189 - 1197
Journal Title
APPLIED MAGNETIC RESONANCE
Volume
46
Number
11
Start Page
1189
End Page
1197
URI
https://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/9974
DOI
10.1007/s00723-015-0713-0
ISSN
0937-9347
Abstract
The aim of this study was to obtain high-resolution images with a short acquisition time using a compressed sensing (CS) technique for microvascular imaging, especially of the lenticulostriate arteries (LSAs), with 7T magnetic resonance imaging (MRI). Initially, two different radio frequency (RF) coils, birdcage and multi-channel phased array, were tested to compare images of micro-vessels acquired using the CS technique with those acquired using conventional magnetic resonance angiography (MRA) at 7T MRI. High-resolution CS MRA as well as low- and high-resolution conventional time-of-flight MRA images obtained with a multi-channel RF coil was compared to evaluate the feasibility of the CS technique for microvascular imaging. Signal intensities were then used to quantitatively estimate vessel sizes. Compared to low-resolution MRA, the CS technique improved the depiction of the LSAs and provided a substantially reduced partial volume effect of the vessels. Despite the short acquisition time of the CS technique, it clearly depicted the LSA morphology almost as well as the high-resolution MRA. The measured size difference between micro-vessels that were analyzed using the CS technique and those analyzed using high-resolution MRA was about 20 %; however, the difference between the high-resolution and the low-resolution MRA was as high as 100 %. This study evaluated the feasibility of the CS technique for microvascular imaging with 7T MRI. A CS technique that combines high-resolution imaging with a short acquisition time would be a very effective method for microvascular imaging in both research and clinical studies.
Files in This Item
There are no files associated with this item.
Appears in
Collections
보건과학대학 > 방사선학과 > 1. Journal Articles
보건과학대학 > 의용생체공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Hang Keun photo

Kim, Hang Keun
College of IT Convergence (의공학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE