Development of skeletal systems for ICRP pediatric mesh-type reference computational phantoms

Authors
Choi, ChansooShin, BanghoYeom, Yeon SooHan, HaeginHa, SangseokMoon, SunghoSon, GaheeNguyen, Thang TatKim, Chan HyeongChung, Beom SunBolch, Wesley E.
Issue Date
Jun-2021
Publisher
IOP PUBLISHING LTD
Keywords
ICRP reference phantom; pediatric phantom; skeletal system; mesh; voxel; Monte Carlo simulation
Citation
JOURNAL OF RADIOLOGICAL PROTECTION, v.41, no.2, pp.139 - 161
Indexed
SCIE
SCOPUS
Journal Title
JOURNAL OF RADIOLOGICAL PROTECTION
Volume
41
Number
2
Start Page
139
End Page
161
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/1060
DOI
10.1088/1361-6498/abd88d
ISSN
0952-4746
Abstract
In 2016, the International Commission on Radiological Protection (ICRP) launched Task Group 103 (TG 103) for the explicit purpose of developing a new generation of adult and pediatric reference computational phantoms, named ‘mesh-type reference computational phantoms (MRCPs)’, that can overcome the limitations of voxel-type reference computational phantoms (VRCPs) of ICRP Publications 110 and 143 due to their finite voxel resolutions and the nature of voxel geometry. After completing the development of the adult MRCPs, TG 103 has started the development of pediatric MRCPs comprising 10 phantoms (male and female versions of the reference newborn, 1-year-old, 5-year-old, 10-year-old, and 15-year-old). As part of the TG 103 project, within the present study, the skeletal systems, one of the most important and complex organ systems of the body, were developed for each phantom age and sex. The developed skeletal systems, while closely preserving the original bone topology of the pediatric VRCPs, present substantial improvements in the anatomy of complex and/or small bones. In order to investigate the dosimetric impact of the developed skeletons, the average absorbed doses and the specific absorbed fractions for radiosensitive skeletal tissues (i.e. active marrow and bone endosteum) were computed for some selected external and internal exposure cases, which were then compared with those calculated with the skeletons of pediatric VRCPs. The comparison result showed that the dose values of the pediatric MRCPs were generally similar to those of the pediatric VRCPs for highly penetrating radiations (e.g. photons >200 keV); however, for weakly penetrating radiations (e.g. photons ≤200 keV and electrons), significant differences up to a factor of 140 were observed.
Files in This Item
Go to Link
Appears in
Collections
서울 공과대학 > 서울 원자력공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Chan Hyeong photo

Kim, Chan Hyeong
COLLEGE OF ENGINEERING (DEPARTMENT OF NUCLEAR ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE