Detailed Information

Cited 6 time in webofscience Cited 3 time in scopus
Metadata Downloads

The diagnostic performance of novel torque technique for endoscopic ultrasound-guided tissue acquisition in solid pancreatic lesions: A prospective randomized controlled trial

Authors
Park, Se WooLee, Sang SooSong, Tae JunKoh, Dong HeeHyun, BomiChung, DoocheolLee, JinShin, EunHong, Seung-MoPark, Chan Hyuk
Issue Date
Mar-2020
Publisher
WILEY
Keywords
endoscopic ultrasound; histologic core; solid pancreatic lesion; tissue acquisition; torque
Citation
JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, v.35, no.3, pp.508 - 515
Indexed
SCIE
SCOPUS
Journal Title
JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY
Volume
35
Number
3
Start Page
508
End Page
515
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/10678
DOI
10.1111/jgh.14840
ISSN
0815-9319
Abstract
Background and Aim Although several techniques for improved outcomes in endoscopic ultrasound (EUS)-guided tissue acquisition have been reported, the reported diagnostic yield for pancreatic masses is not satisfactory. The effects of novel technique (torque method) on twisting the scope in the clockwise or counterclockwise direction during EUS-fine needle biopsy (EUS-FNB) are unknown. We compared the diagnostic yield of EUS-FNB for pancreatic masses using the torque and standard techniques. Methods From April 20, 2017, to March 16, 2018, 124 consecutive patients with solid pancreatic mass who underwent EUS-FNB using either the torque or standard technique were randomly assigned. Three passes were made with each technique, comprising 10 uniform to-and-fro movements on each pass with a 10-mL syringe suction. The primary outcome was procurement rates of histologic cores, and the secondary outcomes were the diagnostic performance and technical failure. Results There were significant differences between the groups regarding the procurement rate of the histologic core and optimal quality core (standard vs torque: 87.1% [54/62] vs 98.4% [61/62], P = 0.038 and 79.0% [49/62] vs 93.5% [58/62], P = 0.037). The sensitivity, specificity, positive predictive value, and negative predictive values of EUS-FNB were 85.45%, 100%, 100%, and 46.67%, respectively, for the standard technique and 96.49%, 100%, 100%, and 71.43%, respectively, for the torque technique. The diagnostic accuracies of the standard and torque techniques were 87.10% and 96.77%, respectively. Conclusions The torque technique for EUS-FNB offered acceptable technical feasibility and superior diagnostic performance, including optimal histologic core procurement, compared with the standard technique.
Files in This Item
Go to Link
Appears in
Collections
서울 의과대학 > 서울 내과학교실 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Park, Chan Hyuk photo

Park, Chan Hyuk
COLLEGE OF MEDICINE (DEPARTMENT OF INTERNAL MEDICINE)
Read more

Altmetrics

Total Views & Downloads

BROWSE