Abstract
Two-phase flow, particularly generated in an expansion device, is a primary cause of refrigerant-induced noise in an air-conditioning system. The indoor unit (IDU) of a multi-split air source heat pump (ASHP) for both heating and cooling must include an electric expansion valve (EEV); therefore, consumers have perceived the increased noise. To reduce this noise, we experimentally investigated the two-phase flow and consequent noise by applying a honeycomb and porous metal as a flow conditioner to the EEV in the IDU of a multi-split ASHP. Flow conditioning near the EEV with the honeycomb and porous metal made the two-phase flow steadier and more uniform, leading to reduced noise and frequency variation for the three heat operation modes of a multi-split ASHP. The noise reduction was also verified in the transient operating modes of a real IDU.
Files in This Item
Go to Link
Appears in
Collections
서울 공과대학 > 서울 기계공학부 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Song, Simon photo

Song, Simon
COLLEGE OF ENGINEERING (SCHOOL OF MECHANICAL ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE