Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Preliminary evacuation time estimate in Korea and its application into level 3 PSA

Authors
Park, SunghyunSohn, SeokwooPark, HyunaeJae, Moo sung
Issue Date
2020
Publisher
Research Publishing Services
Keywords
Emergency Response Model; EPZ; Evacuation; Evacuation Time Estimate; Level 3 PSA; Public Protection Measure
Citation
Proceedings of the 29th European Safety and Reliability Conference, ESREL 2019, pp.3839 - 3846
Indexed
SCOPUS
Journal Title
Proceedings of the 29th European Safety and Reliability Conference, ESREL 2019
Start Page
3839
End Page
3846
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/11535
DOI
10.3850/978-981-11-2724-3_0407-cd
ISSN
0000-0000
Abstract
Level 3 PSA(Probabilistic Safety Assessment) concerns the dispersion and effects of a radioactive release resulting from an accident at a nuclear power plant. It is often called a consequence analysis. Consequences result from the radioactive material released in a severe accident. Level 3 PSA estimates those consequences such as health effects such as short-term injuries or long-term cancers. The health effects depend on the population in the plant vicinity, evacuation conditions, and weather conditions. In the early stage of the accident, there are public protection measures such as sheltering and evacuation. There are many factors affecting the early protection measures. Hence, the early protection measures considering these factors should be assessed for setting the emergency response model in Level 3 PSA. It is called analysis of ETE(Evacuation Time Estimate). ETE is to calculate the time to evacuate the plume exposure pathway EPZ(Emergency Planning Zone). The purpose of ETE is to provide a tool for preplanning protective action decision making and inputs for constructing the emergency response model. However, the emergency response model has considerable uncertainties and huge impact on consequence results. Therefore, ETE analysis is very important to reduce the uncertainty of Level 3 PSA. However, ETE analysis was not performed properly in Korea. Therefore, the purposes of this study are to perform ETE analysis, concern the uncertainty factors and suggest the way to reduce uncertainties.
Files in This Item
Go to Link
Appears in
Collections
서울 공과대학 > 서울 원자력공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Jae, Moo sung photo

Jae, Moo sung
COLLEGE OF ENGINEERING (DEPARTMENT OF NUCLEAR ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE