Detailed Information

Cited 4 time in webofscience Cited 3 time in scopus
Metadata Downloads

Comparison of Linear and Nonlinear Ultrasonic Parameters in Characterizing Grain Size and Mechanical Properties of 304L Stainless Steelopen access

Authors
Choi, SunghoRyu, JuyoungKim, Jae-SeungJhang, Kyung-Young
Issue Date
Dec-2019
Publisher
Multidisciplinary Digital Publishing Institute (MDPI)
Keywords
grain size; ultrasonic velocity; ultrasonic attenuation coefficient; nonlinear ultrasonic parameter; 304L stainless steel
Citation
Metals, v.9, no.12
Indexed
SCIE
SCOPUS
Journal Title
Metals
Volume
9
Number
12
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/11625
DOI
10.3390/met9121279
Abstract
Ultrasonic nondestructive techniques can be used to characterize grain size and to evaluate mechanical properties of metals more practically than conventional destructive optical metallography and tensile tests. Typical ultrasonic parameters that can be correlated with material properties include ultrasonic velocity, ultrasonic attenuation coefficient, and nonlinear ultrasonic parameters. In this work, the abilities of these ultrasonic parameters to characterize the grain size and the mechanical properties of 304L stainless steel were evaluated and compared. Heat-treated specimens with different grain sizes were prepared and tested, where grain size ranged from approximately 40 to 300 mu m. The measurements of ultrasonic velocity and ultrasonic attenuation coefficient were based on a pulse-echo mode, and the nonlinear ultrasonic parameter was measured based on a through-transmission mode. Grain size, elastic modulus, yield strength, and hardness were measured using conventional destructive methods, and their results were correlated with the results of ultrasonic measurements. The experimental results showed that all the measured ultrasonic parameters correlated well with the average grain size and the mechanical properties of the specimens. The nonlinear ultrasonic parameter provided better sensitivity than the ultrasonic velocity and the ultrasonic attenuation coefficient, which suggests that the nonlinear ultrasonic measurement would be more effective in characterizing grain size and mechanical properties than linear ultrasonic measurements.
Files in This Item
Appears in
Collections
서울 공과대학 > 서울 기계공학부 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Jhang, Kyung Young photo

Jhang, Kyung Young
COLLEGE OF ENGINEERING (SCHOOL OF MECHANICAL ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE