Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Stretchable, patch-type calorie-expenditure measurement device based on pop-up shaped nanoscale-crack based sensor

Authors
Kwon, Ki YoonShin, Yiel JaeShin, Joo HwanJeong, ChanhoJung, Yei HwaPark, ByeonghaKim, Tae-il
Issue Date
Oct-2019
Publisher
WILEY
Keywords
calories expenditure; nanoscale crack-based sensor (NCbS); pop-up shaped sensor; stretchable sensor
Citation
ADVANCED HEALTHCARE MATERIALS, v.8, no.19, pp.1 - 8
Indexed
SCIE
SCOPUS
Journal Title
ADVANCED HEALTHCARE MATERIALS
Volume
8
Number
19
Start Page
1
End Page
8
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/12404
DOI
10.1002/adhm.201801593
ISSN
2192-2640
Abstract
Demands for precise health information tracking techniques are increasing, especially for daily dietry requirements to prevent obesity, diabetes, etc. Many commercially available sensors that detect dynamic motions of the body lack accuracy, while novel strain sensors at the research level mostly lack the capability to analyze measurements in real life conditions. Here, a stretchable, patch-type calorie expenditure measurement system is demonstrated that integrates an ultrasensitive crack-based strain sensor and Bluetooth-enabled wireless communication circuit to offer both accurate measurements and practical diagnosis of motion. The crack-based strain gauge transformed into a pop-up-shaped structure provides reliable measurements and broad range of strain (approximate to 100%). Combined with the stretchable analysis circuit, the skin attachable tool translates variation of the knee flexion angle into calorie expenditure amount, using relative resistance change (R/R-0) data from the flexible sensor. As signals from the knee joint angular movement translates velocity and walking/running behavior, the total amount of calorie expenditure is accurately analyzed. Finally, theoretical, experimental, and simulation analysis of signal stability, dynamic noises, and calorie expenditure calculation obtained from the device during exercise are demonstrated. For further applications, the devices are expected to be used in broader range of dynamic motion of the body for diagnosis of abnormalities and for rehabilitation.
Files in This Item
Go to Link
Appears in
Collections
서울 공과대학 > 서울 융합전자공학부 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Jung, Yei Hwan photo

Jung, Yei Hwan
COLLEGE OF ENGINEERING (SCHOOL OF ELECTRONIC ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE